Using the Thermal Cycle CAD and what it assumes
A series on the Thermal Cycle CAD, which links pumps, boilers, turbines, condensers and more into closed cycles of steam, air or refrigerant and calculates their operating point, efficiency and state diagrams: how to use it and what the calculations assume. Every part's calculations open as shared results.
The Thermal Cycle CAD builds closed cycles in which a working fluid (water/steam, air, or the refrigerant R134a) goes round the equipment and returns, and calculates the pressure, temperature and enthalpy of each state point, the heat and work of each block, the cycle efficiency and diagrams such as T–s and P–h. It uses TESPy (a network solver for thermal cycles) and CoolProp (properties; IAPWS-IF97 for water and steam).
Unlike the Chemical and Engineering CADs, a cycle is a ring and has no “upstream”. So “where is the flow set?” and “which conditions, and how many, must be given?” are the keys to using it. This series explains the steps of using the CAD together with the assumptions of its calculations.
## What the series covers
For people using the Thermal Cycle CAD for the first time, the series starts from placing blocks and drawing lines. Parts 1 to 6 use the same simple Rankine cycle (pump, boiler, turbine, condenser); part 7 onwards builds on it.
- Part 1, what is a thermal cycle?: the journey of water in a power plant, and the words used in the series
- Part 2, the screen, placing blocks and drawing lines
- Part 3, entering conditions and calculating: pressure regions, and why the flow is given in one place
- Part 4, reading the results: tables and the energy balance (working it out per kilogram yourself)
- Part 5, reading the diagrams: T–s and P–h
- Part 6, comparing cases, saving and sharing
- Part 7, calculation purposes and the number of conditions: finding the Rankine cycle for 10 MW of net shaft output
- Part 8, how performance is given: entering catalogue efficiencies as they are (where losses go, generating efficiency)
- Part 9, a condenser cooled by cooling water, machine capacities and the four checks
- Part 10, reheat and regeneration: heating the feedwater with bled steam
- Part 11, changing the working fluid: a refrigerator's cycle and a gas turbine's Brayton cycle
- Part 12, Pilot Mode: running the cycle you built
There is also a series that calculates a gas turbine step by step (Gas turbines step by step).
- The numbers of every part are calculated with Laplaxian's engine. The conditions are chosen for explanation; they are not recommended or standard values.
- What is a thermal cycle? The journey of water in a power plant — Before touching the Thermal Cycle CAD, this part introduces what it calculates: the four machines of the Rankine cycle, which boils water, turns a turbine and cools the steam back to water, and the words used throughout the series (pressure, temperature, mass flow, heat and work, specific enthalpy, quality, efficiency), with a kettle and a pinwheel as the picture.
- The screen, placing blocks and drawing lines — This part shows where everything is on the Thermal Cycle CAD's screen and goes step by step through placing the four machines — pump, boiler, turbine, condenser — and joining them with lines into a ring. It also explains the messages shown when a line cannot be drawn and how to fix them, how to delete a wrong line, and the kinds of lines (working fluid, cooling water, shaft).
- Entering conditions and calculating — The four machines joined in part 2 get the boiler's outlet pressure and temperature, the turbine's and pump's efficiencies and the condenser's pressure, the cycle's flow is set to 10 kg/s, and the cycle is calculated. The part explains why the turbine and pump get no outlet pressure (pressure regions), why the flow is given in one place only, and what the console says when something is deliberately wrong.
- Reading the results: tables and the energy balance — The simple Rankine cycle calculated in part 3 is read in order: “Results (whole system)” on the right, then the state table, blocks and system tabs of the full-screen “Thermal cycle results”. From differences of specific enthalpy you work out the heat and work per kilogram of water and steam yourself, and check the energy balance (heat in = work + heat thrown away) and the efficiency of 36.07 %.
- Reading the diagrams: the T–s and P–h diagrams — The simple Rankine cycle calculated in part 3 is looked at in the T–s and P–h diagrams of the results' “Diagrams” tab. The part explains what the inside and outside of the dome-shaped saturation line mean, which line each of the four machines draws, how the gap between the turbine's ideal (dashed) line and its real line shows its loss, and how horizontal lengths on the P–h diagram are the heat and work per kilogram.
- Comparing cases, saving and sharing — Taking part 3's simple Rankine cycle as the base case, the boiler outlet temperature, the condenser pressure, the turbine efficiency and the flow are changed one at a time and the “Compare” tab shows how the efficiency, output and quality change. The part also explains sweeping one value step by step, saving the cycle and its results, and sharing a result by a link.
- Calculation purposes and the number of conditions | Finding the Rankine cycle for 10 MW of net shaft output — A net shaft output of 10 MW needs a flow of 8.746 kg/s. The same Rankine cycle is calculated two ways — with the flow specified as 10 kg/s and with the net shaft output specified as 10 MW — and compared. The part explains what the calculation purpose (whether the flow, the heat input or the net output is given) changes and what it does not, why seven conditions are needed, and what happens with too few or too many.
- How performance is given: entering catalogue efficiencies as they are — Catalogue efficiencies divide different things by different things from machine to machine. Giving the pump an overall efficiency with its motor, the turbine a shaft output ratio with a mechanical efficiency and the boiler an efficiency (LHV), and connecting a generator to the turbine's shaft, this part finds the shaft and electric outputs, the fuel heat and the generating efficiency. It explains the assumptions about where losses go and how no loss is counted twice.
- A condenser cooled by cooling water, machine capacities and the four checks — The condenser pressure, so far fixed at 10 kPa, now comes out of a calculation with cooling water (20 °C, 600 kg/s) and a heat-transfer size UA. The part explains how to connect the cooling-water lines, why the condensing pressure becomes a result, and how to read the “four checks” (calculation, balance, capacity, physical conditions) with capacity limits on the boiler and pump and a minimum turbine exhaust quality.
- Reheat and regeneration: heating the feedwater with bled steam — Adding reheat (back to 500 °C at 2 MPa) and an open feedwater heater fed by steam bled at 0.5 MPa to the simple Rankine cycle raises the efficiency from 36.07 % to 40.59 %. The part explains how the splitter and merge blocks are placed and set, why the bleed flow comes out as a result, and why the efficiency rises.
- Changing the working fluid: a refrigerator's cycle and a gas turbine's Brayton cycle — Switching the working fluid to the refrigerant R134a, this part calculates the vapour-compression refrigeration cycle of refrigerators and air conditioners (COP 3.27). It explains how heat is carried from a low temperature to a high one and the COP used instead of an efficiency, and introduces gas turbines running on air (the Brayton cycle) and calculations with compressor and turbine maps.
- Pilot Mode: running the cycle you built — Pilot Mode lets you change a finished cycle's operating values (the boiler's outlet temperature, the condenser pressure, the flow, …) one at a time, like an operator, and see a new operating point on the instruments each time. The part shows an example of running the simple Rankine cycle and a shared pilot (a gas turbine) that can be operated without an account.