Using the Thermal Cycle CAD and what it assumes — 7 / 12

Calculation purposes and the number of conditions | Finding the Rankine cycle for 10 MW of net shaft output

A net shaft output of 10 MW needs a flow of 8.746 kg/s. The same Rankine cycle is calculated two ways — with the flow specified as 10 kg/s and with the net shaft output specified as 10 MW — and compared. The part explains what the calculation purpose (whether the flow, the heat input or the net output is given) changes and what it does not, why seven conditions are needed, and what happens with too few or too many.

In part 3 the flow was set to 10 kg/s and the output, 11.434 MW, was found. Real design often goes the other way: “we want a 10 MW plant — how much steam must go round?”

In the Thermal Cycle CAD, the size of a cycle (how much working fluid goes round) is given once, by the “calculation purpose” in the system's calculation conditions. If the flow is known, the output can be found (flow given); if a target output is set, the flow it needs can be found (net power given).

The net shaft output here is the work the turbine gives out at its shaft minus the work used to turn the pump. This part solves the same Rankine cycle both ways — flow given (10 kg/s at the boiler outlet) and net power given (10 MW net shaft output) — and compares them.

## A curry recipe
A curry recipe says “with this much of each ingredient you get so many servings”. Deciding the amount of ingredients (the flow) and finding how much you get (the output) is flow given.

Deciding first “today I want eight servings” and working back to the ingredients needed is net power given. Either way the taste of the curry (what is in one serving — the cycle's states and efficiency) is the same; only the total amount changes.

## Kinds of calculation purpose
Purpose — You give — Found
Flow given — the mass flow at one state point — output, heat input, heat rejected
Heat input given — the heat the chosen heaters give the working fluid (or the fuel heat input) — flow, output
Net power given — net shaft output (turbines − pumps) or net electric output — flow, heat input
Operating point from maps — compressor and turbine maps and speeds (the part on working fluids and maps) — flow, pressure ratio, efficiencies
Balance check of measurements — measured states, flows, heats and powers — how far the balances disagree (no equations are solved)
## This example needs seven conditions
The conditions that fix the Rankine cycle's states and size are these seven (the same as entered in part 3).

- Pressures (two): one per region joined by machines that keep the pressure (boiler, condenser) — a pressure region. The boiler's outlet pressure 10 MPa for the high-pressure region (pump outlet to turbine inlet) and the condenser pressure 10 kPa for the low-pressure region (turbine outlet to pump inlet).
- Outlet states of the boiler and condenser (two): the boiler outlet temperature 500 °C and the condenser subcooling 0 K (saturated liquid leaves).
- Efficiencies of the turbine and pump (two): both given as “Isentropic efficiency”: the turbine 0.9, the pump 0.75.
- The cycle's size (one): the value of the calculation purpose (a flow of 10 kg/s, or a net shaft output of 10 MW).

With fewer than seven (say the condenser pressure deleted) or more (an outlet pressure on the pump as well), the Laplaxian Console below says which pressure region or which machine's condition is missing or doubled (checked at every edit, without calculating). “▶ Calculate” makes the final check; a cycle with missing or doubled conditions is not calculated, and no condition is removed or added automatically.

## How it is used
1. Enter the six conditions other than the size in the blocks (part 3's cycle can be used as it is).
2. Press an empty spot of the canvas; in “Calculation conditions (whole cycle)” on the right set the purpose to “Flow given”, the point with the given mass flow to “2: Boiler / heater → Turbine” and the mass flow to 10 kg/s.
3. Press “▶ Calculate” in the toolbar.
4. Switch the purpose to “Net power given”, count the net output as “net shaft output (turbines − pumps)” and enter 10 MW. The flow field disappears (the flow is now an answer).
5. Press “▶ Calculate” again.

## Comparing flow given and net power given
— Flow given (10 kg/s) — Net power given (10 MW)
Mass flow — 10 kg/s (entered) — 8.746 kg/s
Net shaft output — 11.434 MW — 10 MW (entered)
Boiler heat input — 31.698 MW — 27.722 MW
Cycle efficiency — 36.07 % — 36.07 %
State points (temperature, pressure, quality) — the same in both calculations — the same in both calculations
With the machines' conditions the same, every state point's temperature, pressure and specific enthalpy is the same in both calculations, so the heat input and the net work per kilogram of water and steam are the same too (3169.8 kJ/kg and 1143.4 kJ/kg in part 4's table). Reducing the flow therefore reduces the heat input and the output in the same proportion (by 10 ÷ 11.434 = 0.8746), and the efficiency stays at 36.07 %. The flow needed can also be worked out by hand: 10 MW ÷ 1143.4 kJ/kg of net work per kilogram = 8.746 kg/s. Giving a heat input of 27.722 MW to the boiler with the purpose “Heat input given” gives the same 8.746 kg/s.

## Assumptions
- Size targets are met by iterating the flow: with heat input or net power given, the flow on one loop connection is varied and the whole cycle solved each time until the target is met (the secant method). Results are not scaled with the flow, so conditions under which the operating point depends on the flow, like a cooling-water UA, are still solved correctly.
- A closed loop: the working fluid circulates in a closed loop and neither enters nor leaves. For the solver, a “closer” is placed somewhere in the loop automatically; any mass mismatch is reported as the loop-closure residual (no heat, work or pressure is added).
- Lumped and steady: each machine is represented by its inlet and outlet states; kinetic and potential energy are left out.
- Counting heat input: with heat input given you choose the heaters to count (include the reheater by selecting it). A fuel heat input needs each heater's boiler efficiency and the heating-value basis (HHV / LHV) (the part on fuel heat input and heating values).

## The flow needed
\dot m = \frac{P_{\mathrm{net}}}{(h_2 - h_3) - (h_1 - h_4)} = \frac{10\,000\ \mathrm{kW}}{1156.9 - 13.5\ \mathrm{kJ/kg}} = 8.746\ \mathrm{kg/s}

Shared result: aiming at a net shaft output of 10 MW (opens without an account or login)

## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).

- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).

## What to try next
- Switch to heat input given with 30 MW at the boiler: what are the flow and the net output?
- Give the pump an outlet pressure of 10 MPa as well and see what the console says.

- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.

How performance is given: entering catalogue efficiencies as they are