Using the Thermal Cycle CAD and what it assumes — 6 / 12

Comparing cases, saving and sharing

Taking part 3's simple Rankine cycle as the base case, the boiler outlet temperature, the condenser pressure, the turbine efficiency and the flow are changed one at a time and the “Compare” tab shows how the efficiency, output and quality change. The part also explains sweeping one value step by step, saving the cycle and its results, and sharing a result by a link.

One calculation only tells you “under these conditions, this happens”. Changing conditions and comparing — “what if the steam were hotter?”, “what if the cooling were better?” — shows how much each condition matters for the efficiency and output. That is the basis of design thinking.

The calculated cycle and its results can also be saved, and a result can be shown to others by a link.

## Change one thing at a time, as in a science experiment
In an experiment on how plants grow, changing the sunlight and the water at the same time does not tell you which one mattered. The rule is to change only one thing per experiment and keep everything else the same (a controlled experiment).

Comparing thermal cycles works the same way: fix one base calculation, change just one condition from it, calculate, and look at the difference from the base.

## How to compare
1. Calculate part 3's cycle (or place the tutorial “Simple Rankine” and calculate it).
2. In “📊 Results” → the “Compare” tab, press “Use this result as the base case”.
3. Close the results, change just one condition and press “▶ Calculate”.
4. Open the “Compare” tab again: the base and the new calculation appear side by side with their differences. “Changed conditions” lists what was changed, automatically.

The base case is remembered until you close that browser tab. To compare another condition, put the value back first, then change the next one. Efficiency differences are shown in “points” (36.07 % → 36.76 % is +0.69 points).

## Four conditions changed one at a time
The base: boiler outlet 10 MPa and 500 °C, condenser 10 kPa, turbine efficiency 0.9, pump efficiency 0.75, flow 10 kg/s.
Condition changed — Cycle efficiency — Net shaft power — Turbine exhaust quality
base — 36.07 % — 11.43 MW — 0.847
boiler outlet temperature 500 → 550 °C — 36.76 % — 12.12 MW — 0.872
condenser pressure 10 → 7 kPa — 36.90 % — 11.80 MW — 0.838
turbine isentropic efficiency 0.9 → 0.8 — 32.02 % — 10.15 MW — 0.901
flow 10 → 20 kg/s — 36.07 % — 22.87 MW — 0.847
## What the results tell you
- Hotter steam (550 °C): efficiency, output and quality all rise. Hotter steam can do more work over the same pressure drop, and the turbine exhaust has fewer droplets.
- Better cooling (7 kPa): a lower condenser pressure lowers the temperature at which the water returns from 45.8 °C to about 39 °C, and the turbine can expand to a lower pressure, so the efficiency rises. In exchange the exhaust quality falls (more droplets). In a real plant the cooling water's temperature sets this pressure (the part on a condenser with cooling water).
- A worse turbine (0.8): the efficiency falls by more than 4 points. The quality rises because the heat of the losses stays in the steam (part 5).
- Double the flow: the output exactly doubles, but the efficiency and quality do not change. Every state point keeps its pressure and temperature, so the heat and work per kilogram stay the same. The flow sets “how big” the cycle is, not “how good”.

## Sweeps: changing one value step by step
The “Sweep” tab of “📊 Results” calculates a series of cases with one value changed step by step over a range and shows how the efficiency changes, as a graph and a table.

1. In “Value to vary”, choose, say, the boiler outlet temperature.
2. Enter the start and end (say 400 °C and 600 °C) and the number of points.
3. Run it: each point is calculated once as an ordinary calculation, and finished points appear in the table and graph.

A point that could not be calculated is left blank (missing), not 0, so you can also see where calculations stop working.

## Saving
There are two kinds of saving.
Button — What is saved
Save cycle — the cycle on the canvas (machines, lines, entered conditions, layout). Name it in the name field of the toolbar. It overwrites
Save result — the last calculation's result, added under a name together with the cycle at that time. Changing conditions later does not change a saved result
“Save result” can be pressed only after the cycle has been saved and while the conditions are unchanged since the calculation. Saved items open from “Saved” in the toolbar. A saved result opens as it was saved (it is not recalculated).

## Sharing
1. In “Saved”, press a cycle's “Results” to list them.
2. Tick “Share (viewer)” under a result; a link is made.
3. Press “Copy link” and send it to whoever should see it.

Anyone opening the link sees the flowsheet, inputs, results and diagrams without an account or login (view only; they cannot change conditions or calculate). Untick it and the link stops opening. The “shared result” links in these articles were made the same way.

## Rules of comparisons and sweeps
- Matching: a comparison matches machines and state points by their internal IDs. Between calculations with machines added or removed, rows without a match cannot be compared.
- Different size conditions: comparing calculations with different size conditions, such as constant flow and constant output, shows the warning “not a comparison under the same conditions”.
- Each sweep point is an ordinary calculation: with the same input checks; a calculation with the same conditions reuses the earlier result (a calculation with the same fingerprint is not repeated). Capacity limits are not swept (changing only a limit does not change the operating point).
- Why the flow does not change the efficiency: with every machine's conditions (pressures, temperatures, efficiencies) the same, the enthalpy differences per kilogram do not depend on the flow, so heat and work are both proportional to it and their ratio, the efficiency, does not change. When conditions such as a cooling-water flow or a heat-transfer area (UA) set the operating point, the states change with the flow too.
- Saved results: a saved result is a snapshot of the calculation; it opens as it was even after the engine's models change.

## The base case as a shared result
The calculation used as the base of the comparisons.

Shared result: the simple Rankine cycle (opens without an account or login)

## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).

- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).

- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.

Calculation purposes and the number of conditions | Finding the Rankine cycle for 10 MW of net shaft output