Using the Thermal Cycle CAD and what it assumes — 4 / 12
Reading the results: tables and the energy balance
The simple Rankine cycle calculated in part 3 is read in order: “Results (whole system)” on the right, then the state table, blocks and system tabs of the full-screen “Thermal cycle results”. From differences of specific enthalpy you work out the heat and work per kilogram of water and steam yourself, and check the energy balance (heat in = work + heat thrown away) and the efficiency of 36.07 %.
When a calculation finishes, many numbers appear. Knowing which ones matter and how they relate lets you check for yourself whether a result can be trusted.
This part first looks at the overall answer (efficiency and output), then follows the numbers of the tables to see how that answer is built up. Finally it reproduces the Thermal Cycle CAD's answer with calculations you could do on a calculator.
## Like a pocket-money book
In a month's pocket-money book, “money received = money spent + money left” always holds. If a number does not add up, something was written down wrong.
The energy of a thermal cycle is the same. In a cycle running steadily, every second
heat put in at the boiler = (turbine work − pump work) + heat thrown away at the condenser
because energy neither appears nor disappears on the way (conservation of energy). Make it a habit to check this equation first when you read a result.
## 1. Look at the overall answer first
When the calculation finishes, press an empty spot of the canvas. “Results (whole system)” appears at the top of the right panel.
Item — Value — Meaning
Cycle thermal efficiency — 36.07 % — the fraction of the heat put in that became net work
Net shaft output — 11.43 MW — the turbine's work minus the pump's work
Heat input to the working fluid — 31.70 MW — the heat the water and steam received in the boiler
Heat rejected (condensers, coolers) — 20.26 MW — the heat thrown away in the condenser
Check with the pocket-money equation: 11.43 + 20.26 = 31.69 ≈ 31.70 MW (only a rounding difference). It adds up.
The display units can be changed with the unit selectors at the top of the results (kPa / MPa, °C / K, kg/s / t/h, kW / MW).
## 2. Open the full-screen results
Press “📊 Open results (state table, diagrams)” on the card, or “📊 Results” in the toolbar, to open the full-screen “Thermal cycle results”. Tabs run along the top.
Tab — Contents
System and verdicts — efficiency, output and other indicators with how each was found; checks of whether the calculation went well
State table — pressure, temperature and so on of each line (state point)
Blocks — heat and work of each machine
Diagrams — graphs such as the T–s diagram (part 5)
Compare, Sweep — comparing with calculations under other conditions (part 6)
About — the tools used for the calculation and what is not handled
## 3. Read the state table
The “State table” tab has one row per line, with the state of the water and steam there.
State point — Where — Pressure — Temperature — Specific enthalpy — Specific volume — Phase — Quality
① — pump → boiler — 10 MPa — 46.96 °C — 205.3 kJ/kg — 0.00101 m³/kg — liquid — —
② — boiler → turbine — 10 MPa — 500.0 °C — 3375.1 kJ/kg — 0.0328 m³/kg — vapour — —
③ — turbine → condenser — 10 kPa — 45.81 °C — 2218.2 kJ/kg — 12.43 m³/kg — two-phase — 0.847
④ — condenser → pump — 10 kPa — 45.81 °C — 191.8 kJ/kg — 0.00101 m³/kg — two-phase (saturated liquid) — 0
- Phase: liquid (water only), vapour (steam only), two-phase (water and steam mixed). ④ is “just when everything has become water”, so its quality is 0.
- Temperature: ③ and ④ are both 45.81 °C, because water at 10 kPa boils at 45.81 °C (and steam turns back into water at that temperature). Just as water boils below 100 °C on a high mountain, the lower the pressure, the lower the boiling temperature.
- Specific volume: the volume that 1 kg occupies. The steam at ③ takes 12.43 m³/kg, the water at ④ 0.00101 m³/kg: the condenser shrinks the volume about ten-thousand-fold (as in part 1).
- Quality: 0.847 at ③ means “85 % steam, 15 % fine droplets”. Too many droplets damage the turbine blades, so real designs watch this value too.
- The pump hardly changes the water's temperature (45.81 → 46.96 °C): raising the pressure a thousand-fold warms it by only about 1 °C.
Pressing a line on the canvas also shows that state point's mass flow, pressure, temperature and specific enthalpy on the right.
## 4. Think per kilogram: work it out yourself
Differences of specific enthalpy in the state table give the energy that 1 kg of water and steam receives or gives out in each machine.
Machine — Calculation — Per kg — × 10 kg/s
Pump (uses work) — ① − ④ = 205.3 − 191.8 — 13.5 kJ/kg — 0.135 MW
Boiler (heat in) — ② − ① = 3375.1 − 205.3 — 3169.8 kJ/kg — 31.70 MW
Turbine (work out) — ② − ③ = 3375.1 − 2218.2 — 1156.9 kJ/kg — 11.57 MW
Condenser (heat thrown away) — ③ − ④ = 2218.2 − 191.8 — 2026.4 kJ/kg — 20.26 MW
The net work is 1156.9 − 13.5 = 1143.4 kJ/kg and the efficiency 1143.4 ÷ 3169.8 = 0.3607, that is 36.07 % — the same as the Thermal Cycle CAD's answer.
Per kilogram, the pump's work (13.5 kJ) is only 1.2 % of the turbine's (1156.9 kJ): water takes up so little volume that pushing it up needs little work. This is the back work ratio (pump work ÷ turbine work), shown as 1.17 % in the “System and verdicts” tab.
## 5. Read the blocks tab
The “Blocks” tab lists each machine's heat, work, shaft power and “energy residual”. Check that the values you worked out above (31.70 MW, 11.57 MW, 0.135 MW, 20.26 MW) are there. The table states the direction of each heat and work (in or out) in words and shows its size as a positive number.
The energy residual is how far “energy in − energy out” of the machine fails to balance. 0 W (or a very small value) means the machine's energy balance holds.
## 6. Read the system and verdicts tab
- The calculation conditions entered: the calculation purpose (flow specified) and its value (10 kg/s).
- Indicator table: each indicator's value and “category (how it is found)”. The cycle efficiency's row, for example, says “net shaft power ÷ heat input to the working fluid”, showing which numbers it came from.
- Checks: whether it was calculated (calculation status), whether the energy and mass balances are within tolerance (balance), whether a machine's capacity is exceeded (capacity), and whether, say, the turbine exhaust is too wet (physical conditions), each shown separately. No capacity limits are entered in this example, so capacity is “not evaluated”.
## 7. What the colours mean: entered and calculated
The cells of the result tables are painted in two colours.
Colour — Meaning — In this example
blue (marked “entered”) — an entered value; the calculation was solved to satisfy it — 10 MPa and 500 °C at ②, 10 kPa at ③ and ④, 10 kg/s at ②, …
green — a value found by the calculation — the temperature at ①, the quality at ③, the efficiency, …
Hover over an “entered” mark to see which machine's field it was entered in. The quality 0 at ④ is also fixed by an input: a subcooling of 0 (= saturated liquid leaves).
## How the result numbers are related
- Machine balances: each machine's R_E = \sum \dot m h_{\mathrm{in}} - \sum \dot m h_{\mathrm{out}} + Q - W (energy residual) and mass residual are compared with a tolerance (absolute + relative) for the “balance” check.
- Cycle efficiency = net shaft power ÷ heat input to the working fluid; back work ratio = shaft power of pumps and compressors ÷ turbine shaft power.
- Quality is shown only for a mixture of water and steam (and its ends, saturated liquid and saturated vapour).
- Reference of enthalpy: specific enthalpy and entropy of water and steam use the IAPWS reference (internal energy and entropy 0 for saturated liquid at the triple point). What matters is not a value itself but differences.
- Estimating the pump's work: water hardly compresses, so an ideal pump's work is v\,\Delta p = 0.00101 \times (10\,000 - 10) \approx 10.1 kJ/kg; dividing by the efficiency 0.75 gives about 13.5 kJ/kg, which you can estimate by hand.
- Small temperature differences in the state table: the calculation is solved in pressure and specific enthalpy, and temperatures come from IAPWS-IF97's backward equation T(p, h), which has a small tolerance set by IAPWS; an entered temperature and the table's can differ by about 0.01 K.
## Check with the shared result
Even without calculating yourself, “📊 Results” of this shared result shows every table of this part.
Shared result: the simple Rankine cycle (opens without an account or login)
## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).
- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).
- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.