Using the Thermal Cycle CAD and what it assumes — 12 / 12
Pilot Mode: running the cycle you built
Pilot Mode lets you change a finished cycle's operating values (the boiler's outlet temperature, the condenser pressure, the flow, …) one at a time, like an operator, and see a new operating point on the instruments each time. The part shows an example of running the simple Rankine cycle and a shared pilot (a gas turbine) that can be operated without an account.
So far the parts have used design mode: enter conditions and calculate once with “▶ Calculate”. Even the comparisons of part 6 reopened the results after every change.
Pilot Mode treats the finished cycle like a power plant's control room. Change a value on the control panel and press “▶ Recalculate”: a new operating point is calculated and the instruments, the cycle diagram, the trend (a graph of the changes) and the history are all updated together. You can try one “what if I raise the temperature?” after another.
## Like a flight simulator
A flight simulator lets you practise flying without flying a real plane: you move the controls and see how the instruments change.
Pilot Mode is likewise a tool for running the cycle you built in the Thermal Cycle CAD as a “virtual power plant”. Here, though, turning a knob jumps straight to the next settled state; the way temperatures creep up in between, as in a real plant, is not calculated.
## How it is used
1. Build a cycle in the Thermal Cycle CAD (it need not be saved). Here the simple Rankine cycle of part 3 is used.
2. Press “Pilot” in the toolbar's “Design / Pilot” switch (an account and login are needed).
3. In “Pilot setup” the initial operating point is calculated and whether the cycle can be run is judged (READY / LIMITED / BLOCKED).
4. Choose the values to operate (two tabs: “Control panel” and “Other conditions and efficiencies”), their ranges and the instruments to show, then press “Start Pilot”.
5. On the operating screen change a value and press “▶ Recalculate”. The instruments, cycle diagram, trend, comparison and history are updated.
Values changed in the pilot stay in that pilot only. Back in “Design”, the CAD shows the original design unchanged.
## Running the Rankine cycle
With part 3's cycle opened in Pilot Mode, the “Control panel” tab lists the boiler's outlet temperature and pressure and the size target (the flow), and the “Other conditions and efficiencies” tab the turbine's and pump's efficiencies and the condenser pressure. Changing them one at a time and recalculating changes the instruments like this.
Operation — Net shaft output — Cycle efficiency — Turbine exhaust quality
initial operating point (as designed) — 11.434 MW — 36.07 % — 0.847
1. boiler outlet temperature 500 → 550 °C — 12.119 MW — 36.76 % — 0.872
2. then condenser pressure 10 → 7 kPa — 12.497 MW — 37.58 % — 0.862
3. then flow 10 → 12 kg/s — 14.996 MW — 37.58 % — 0.862
- Hotter steam raises the output, efficiency and quality together (as in part 6).
- A lower condenser pressure (better cooling) raises the efficiency but lowers the quality.
- Changing the flow leaves the states and the efficiency unchanged and only scales the output with the flow (as in part 7).
The “Compare” tab lists the differences between the initial point and step 3 (the efficiency +1.51 points).
## The shared gas turbine pilot
The link below is the tutorial “Brayton: the basic gas turbine”, set up to be operated by the control panel (the combustor's outlet temperature and heat, the flow) and the other tab (the pressure ratio, the compressor efficiency, the outlet temperature of the exhaust cooler).
Shared pilot: running a gas turbine (operable without an account; each visitor gets an operating point of their own, separate from other people's operations)
Lower the combustor's outlet temperature from 1400 K to 1300 K and recalculate, for example, and the instruments show the output and efficiency falling. The steps, and how to keep the heat input constant (approving a change of a fixed condition), are in using Pilot Mode.
## What Pilot Mode assumes
- Quasi-steady: each recalculation finds a new steady operating point. Changes over time between operations (warming up, rotating inertia, control delays) are not calculated. The trend's horizontal axis is the operation number, not time.
- The same calculation as design mode: an operating point is the design with the operated values laid over it, sent to the same calculation as design mode's “Calculate”. The values in the table above match design-mode calculations with those values entered.
- Efficiencies stay constant: a machine given a constant efficiency keeps it when outlet temperatures or flows change. To see efficiencies change as in real part-load operation, use a cycle given by maps (its shaft speed can also be operated).
- Changing a fixed condition needs approval: operating a quantity the current settings do not use (the heat of a heater given by its outlet temperature, for example) asks, before calculating, for approval of which condition to drop.
- A failure keeps the previous point: an operation that cannot be calculated is not adopted; the last operating point that was calculated is kept.
## How to use the shared pilot
- It opens at the sharer's initial operating point (opening it does not calculate).
- Only the values of the Controls tab can be changed. Change a value and press “▶ Recalculate”: an operating point of your own is calculated (the sharer and other visitors are not affected).
- Instruments, cycle diagram, trend, comparison, history and log can be viewed. There is no “back to the initial (design) point”; to go back, enter the initial values again and recalculate.
- After 24 hours without an operation your session is removed (opening the link again starts afresh).
## The design the operations start from
Shared result: the simple Rankine cycle (opens without an account or login)
## What to try next
- In the shared pilot, raise the pressure ratio from 10 to 15: how do the efficiency and the output change?
- Open the simple Rankine cycle in Pilot Mode in your own Thermal Cycle CAD and repeat the operations of the table above.
- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.