Using the Thermal Cycle CAD and what it assumes — 9 / 12
A condenser cooled by cooling water, machine capacities and the four checks
The condenser pressure, so far fixed at 10 kPa, now comes out of a calculation with cooling water (20 °C, 600 kg/s) and a heat-transfer size UA. The part explains how to connect the cooling-water lines, why the condensing pressure becomes a result, and how to read the “four checks” (calculation, balance, capacity, physical conditions) with capacity limits on the boiler and pump and a minimum turbine exhaust quality.
In part 3 the condenser pressure was fixed at 10 kPa. In a real power plant the operators cannot choose the condenser pressure freely: the temperature and amount of the cooling water (sea or river water) flowing through the condenser, and the condenser's size, decide how far the steam is cooled — at what pressure it turns back into water.
This part makes the condenser of the simple Rankine cycle built in parts 2 and 3 (boiler outlet 10 MPa and 500 °C, turbine 0.9, condenser 10 kPa, pump 0.75) “Detailed (cooling water and heat transfer)”, runs 600 kg/s of 20 °C cooling water through it and gives the heat-transfer size as UA 1.2 MW/K. The condensing pressure is not entered; it comes out of the calculation.
It also enters machine capacities (the boiler's maximum heat 30 MW, the pump's maximum shaft power 150 kW) and a minimum turbine exhaust quality of 0.88, and has the results checked against them.
## Ice water and lukewarm water
A can of juice cools quickly in ice water and hardly at all in lukewarm water: the colder the cooling side, the colder the cooled side can get.
A condenser is the same. The colder and more plentiful the cooling water and the bigger the tubes' surface, the lower the temperature the steam is cooled to, and the lower the pressure at which it turns back into water. As part 6 showed, a lower condenser pressure lets the turbine do more work, so when the sea warms up in summer, a power plant's efficiency falls.
## Scales do not lighten the bag
Putting a suitcase on the scales may tell you it is “over 23 kg”, but the scales do not take anything out of it. The Thermal Cycle CAD's capacity check is the same: entering that the boiler can give at most 30 MW does not make the calculation look for an operation held at 30 MW; it just reports “the heat needed exceeds the capacity”.
## How it is used
1. Select the condenser of part 3's cycle and set “Model” to “Detailed (cooling water and heat transfer)”. Cooling-water inlet and outlet ports appear on the condenser block.
2. Set the heat-transfer condition to “UA” and enter 1.2 MW/K as the UA (heat-transfer coefficient × area). Leave the condensing pressure empty (the cooling water and UA fix it; entering it would be one condition too many).
3. Place a “Cooling water inlet” and a “Cooling water outlet” from the block list. Give the cooling water inlet a temperature of 20 °C, a pressure (absolute) of 0.2 MPa and a mass flow of 600 kg/s.
4. Draw two lines: the cooling water inlet's “Out” → the condenser's cooling-water inlet, and the condenser's cooling-water outlet → the cooling water outlet's “In”. Both are dotted (cooling-water lines). The cooling water is a separate flow that never mixes with the working fluid; in the condenser it only receives heat through the tube walls.
5. Enter the capacities: the boiler's “Maximum heat” 30 MW under “Capacity and limits (optional)”, the pump's “Maximum shaft power” 150 kW, and the turbine's “Minimum exhaust quality” 0.88.
6. Press “▶ Calculate”.
## What this example found
Item — Value
Condensing pressure (result) — 7.874 kPa (steam turns back into water at 41.21 °C there)
Cooling water — in 20.02 °C → out 28.08 °C, heat received 20.21 MW, minimum temperature difference 13.13 K
Cycle efficiency — 36.63 % (36.07 % at part 3's 10 kPa)
Turbine exhaust quality — 0.841
Boiler heat — 31.89 MW
Pump shaft input — 134.7 kW
System energy balance residual — 0 W (within tolerance)
At 600 kg/s the cooling water warms by about 8 °C, from 20 °C to 28 °C, taking 20.21 MW of heat from the steam on the way. The steam side settles where it turns back into water at 41.2 °C, a little warmer than the cooling water, and the pressure at which water boils at that temperature, 7.874 kPa, becomes the condensing pressure. It is lower than part 3's 10 kPa (45.8 °C), so the efficiency rose by 0.56 points; in exchange the turbine exhaust quality fell.
## The four checks
The checks in “📊 Results” → the “System and verdicts” tab show four things separately.
Check — What it looks at — This example
Calculation status — whether the equations were solved — success
Balance — whether mass and energy in and out agree for each machine and the whole system — within tolerance
Capacity — whether the heat or power needed exceeds the capacity entered — exceeded: the boiler needs 31.89 MW against a maximum of 30 MW (106 % used); the pump's 134.7 kW / 150 kW (90 %) is within
Physical conditions — whether, for example, the turbine exhaust is too wet — warning: exhaust quality 0.841 is below the minimum 0.88
- The checks are independent: the calculation succeeded and the balances hold, yet capacity and physical conditions have problems. Remember that “it could be calculated” and “it can actually be run” are different things.
- A capacity limit does not change the operating point: it only shows that the boiler is about 6 % short. To stay within 30 MW, change a condition yourself — reduce the flow, say — and calculate again.
- Why the 20 °C entered shows as 20.02 °C: the state table's temperatures are recalculated from the pressure and specific enthalpy the calculation found, through IAPWS-IF97's backward equation, which has a small tolerance set by IAPWS (±25 mK for liquid); the 0.02 K difference is within it. The heat is calculated from the 20 °C entered.
## Assumptions when reading the results
- UA and minimum temperature difference: the heat Q the condenser exchanges is set by the temperature difference between cooling water and steam and by UA (heat-transfer coefficient × area). The minimum temperature difference (13.13 K here) is recalculated separately from the solver by dividing both sides into sections.
- In a detailed condenser the condensing pressure is a result: a heat-transfer condition (one of UA, minimum temperature difference or cooling-water outlet temperature) fixes the pressure of that region, so the condensing pressure is not given (with both, the console says there is one condition too many).
- Cooling water is water only: cooling-water flows and the detailed condenser are available only when the working fluid is water and steam.
- Balance check: each machine's R_E = \sum \dot m h_{\mathrm{in}} - \sum \dot m h_{\mathrm{out}} + Q - W and mass residual are compared with a tolerance (absolute + relative).
- Capacities are only compared: the capacity and limit fields are compared with the calculated operating point and do not change it. An empty field means “not evaluated”.
- Diagram lines are reference paths: the lines between a machine's inlet and outlet are reference paths, not the actual states in between (reading thermal cycle diagrams).
Shared result: a condenser with cooling water, and capacities (opens without an account or login)
## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).
- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).
## What to try next
- Raise the cooling water inlet to 30 °C: how do the condensing pressure and the efficiency change? (Think of the sea in summer.)
- Halve the cooling water flow: what happens to its outlet temperature and the minimum temperature difference?
- How far must the flow be reduced for the boiler's capacity check to pass?
- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.