What each block of the Thermal Cycle CAD means

Every block of the Thermal Cycle CAD is a steady model that relates only the states at the equipment's inlets and outlets. Pumps, compressors and turbines exchange work; the boiler / heater, reheater, cooler, evaporator, condenser and pipe exchange heat with the outside; the two-fluid heat exchanger moves heat between two streams. The throttle valve, splitter and merge change the state or divide and join the flow, and the generator and motor convert between shaft power and electricity.

A block carries the name of real equipment but represents only part of its behaviour. The “boiler / heater”, for example, does not model combustion or the furnace's heat transfer: it is a box that adds heat from outside until the outlet reaches the state you give. Knowing what each block represents, and what it leaves out, keeps you from giving the wrong conditions or misreading the results.

A simple Rankine cycle is a ring of four blocks: pump → boiler / heater → turbine → condenser → pump. The heat added in the boiler (heat input) minus the heat removed in the condenser (heat rejected) equals the net shaft output, the turbine's shaft output minus the pump's shaft input (with no mechanical loss and no pipe heat loss; kinetic and potential energy are neglected). A reheat-regenerative Rankine cycle adds a second turbine, a reheater, a splitter (extraction), a merge / open feedwater heater and a second pump.

This page explains the 17 blocks in the Thermal Cycle CAD's block list: what each represents in the calculation (the model), what it connects to (ports), its inputs (the variables you set) and outputs (the result variables), and what is checked. The “?” next to an input explains that field; this page gathers what the blocks themselves mean.

## Contents
- What all blocks share · Reading the input and output tables
- Rotating machines: Pump · Compressor · Turbine
- Heat exchanged with the outside: Boiler / heater · Reheater · Cooler (heat rejection) · Evaporator
- Condensing and heat exchange: Condenser · Heat exchanger (two fluids)
- Blocks that change the flow: Pipe · Throttle valve · Splitter (extraction) · Merge / open feedwater heater
- Power and electricity: Generator · Motor
- Cooling water: Cooling water inlet · Cooling water outlet

## What all blocks share
- Steady lumped models: each block relates only the states at its inlets and outlets (mass flow \dot m, pressure p, specific enthalpy h). The temperature distribution inside, changes over time and the equipment's size are not calculated. Kinetic and potential energy are neglected.
- Line kinds: working fluid (solid), cooling water (dotted), shaft (dashed). Heat is never carried by a line. It enters or leaves across the boundary at the boiler / heater and similar blocks, or moves from the hot to the cold side inside a two-fluid heat exchanger or a detailed condenser.
- Signs: heat \dot Q is positive into the working fluid; work \dot W is positive out of the block (positive for a turbine, negative for a pump or compressor).
- Pressure levels: pumps, compressors, turbines and throttle valves change the pressure, so they separate levels. Every other block (boiler / heater, reheater, cooler, evaporator, pipe, each side of an exchanger or condenser, splitter, merge) keeps its two sides on one level, lowered only by a pressure drop if you give one. A pump given by its total head and a compressor given by its pressure ratio join their two sides into one level. Each level takes exactly one pressure condition (two make the conditions overlap).
- Capability / limits (optional): fields such as maximum flow, maximum duty or rated output describe the equipment and never change the operating point. The results compare them with the required value and show the utilisation and any shortfall; blank means “not evaluated”.
- Working fluids: water (IAPWS-IF97), air or R134a (CoolProp HEOS). The cooling water inlet and outlet and the detailed condenser work in water cycles only, and the condenser only with a condensing fluid (water, R134a).
- Closed loops: to calculate, one “loop closer” is inserted automatically in every loop (at a pump inlet when possible). It adds no heat, work or pressure; its mass deviation is reported as the loop closure residual.

## Reading the input and output tables
Each block's input table has the columns quantity, unit, description and required / optional; its output table has quantity, unit and description (outputs are results, so they have no required / optional column). The quantity names are the field and result names on screen.

The required / optional column

- Required: always enter it; the calculation cannot run with it blank.
- Required (when …): required only with the choice in brackets. Otherwise it is hidden or left blank.
- Optional (default …): it starts with a value; you need not change it.
- Optional: may be left blank; what blank means is in the description.
- Optional (one per pressure level): optional as a field, but on its pressure level exactly one of the fields that set a pressure (discharge pressure, exhaust pressure, outlet pressure, condensing pressure, total head, pressure ratio, the cooling water inlet's pressure) must be entered.

The unit column: the SI units used inside the calculation; every pressure is absolute. On screen you can enter and show pressure in kPa, bar, atm or MPa, temperature in °C, heat and power in kW or MW, mass flow in kg/h and so on. Temperature differences (subcooling, minimum temperature difference) are in K only. “−” marks a quantity without units (a ratio or fraction), “(choice)” a field chosen from options and “(on/off)” a switch. An “initial value” is the rough value a newly placed block starts with, not a recommendation.

Outputs common to every fluid block: every line connected to a block's outlets (and inlets) has the state below. Read it in the state table by the line's number. Each block's output table shows it as one row, “outlet connection state”.
Quantity — Unit — Description
Mass flow — kg/s — The mass flow on that line.
Pressure — Pa — Absolute.
Temperature — K —
Specific enthalpy — J/kg — The reference state (zero) differs between working fluids.
Specific entropy — J/(kg·K) — The reference state differs between working fluids.
Specific volume — m³/kg — The inverse of density.
Phase — (category) — Liquid, two-phase, vapour, supercritical, gas (air).
Quality — − — The mass fraction of vapour. Only in the two-phase region and at its ends (saturated liquid 0, saturated vapour 1); never for air.
The “energy residual” and “mass residual” rows check each block's balances (equations under the technical explanation). “Utilisation” appears only when a capability field is entered; above it, a warning gives the required value, the maximum and the shortfall. With the “balance check of measurements” purpose, the results are the measurements you entered and the heat and work found from the balances (nothing is calculated from the blocks' settings).

## Rotating machines
### Pump block
- Represents: a machine that raises the pressure of a liquid. By default adiabatic: all the work taken from the shaft becomes the fluid's enthalpy rise. Given with its motor (overall efficiency, electric input), you choose where the losses go (losses to the surroundings do not enter the fluid).
- Ports: inlet and outlet (working fluid, required), shaft (input, optional). For an electric output, connect it to a motor or a turbine shaft, so its power is counted exactly once in the electric balance. A pump given by an overall efficiency or electric input includes its motor and has no shaft connection (one is an error).
- Checks: an outlet pressure not above the inlet is an error. An inlet that is not liquid (contains vapour) is warned. A power below what a loss-free pump needs is an error.

Inputs
Quantity — Unit — Description — Required / optional
Performance given by — (choice) — Pump efficiency / overall efficiency / isentropic efficiency / shaft input / electric input. A newly placed pump starts with pump efficiency. Used for: Chooses which field gives the outlet state and the power. Only the chosen method's fields are used; a value in another method's field stops the calculation. — Optional (default isentropic efficiency)
Pump efficiency (water power ÷ shaft input) — − — The catalogue efficiency; water power = \dot m v_1 (p_2-p_1). The whole shaft input goes into the water. Motor losses not included. Above 0, at most 1; initial value 0.75. — Required (pump efficiency)
Overall efficiency (water power ÷ electric input) — − — With the motor. Above 0, at most 1. It fixes the electric input. — Required (overall efficiency)
Isentropic efficiency — − — Loss-free work ÷ actual work. Above 0, at most 1; initial value 0.75. — Required (isentropic efficiency)
Shaft input — W — Positive. All of it goes into the water; the efficiency is a result. — Required (shaft input)
Electric input — W — With the motor. Positive; the efficiency is a result. — Required (electric input)
Where the losses go — (choice) — Overall: all warm the water / all to the surroundings (loss-free rise) / split with a motor efficiency. Electric: all warm the water / split with a motor efficiency. Used for: The assumption that fixes the outlet water state. Unless split with a motor efficiency the shaft input is not fixed, so the shaft input, net shaft output and cycle efficiency are not reported. — Required (overall or electric input)
Motor efficiency (shaft output ÷ electric input) — − — Above 0, at most 1, not below the overall efficiency. Used for: Splits the losses: pump efficiency = overall ÷ motor efficiency, shaft input = electric input × motor efficiency. — Required (when split with a motor efficiency)
Pressure rise given by — (choice) — Discharge pressure / total head. Used for: Chooses whether the discharge pressure or the total head sets the outlet pressure. — Optional (default discharge pressure)
Discharge pressure — Pa — The outlet pressure. Blank: another field on the outlet level sets it (such as the boiler / heater's outlet pressure). Not together with a total head. Used for: Sets the pressure of the outlet pressure level. As the pressure rise, it is used for the outlet state and the pump's shaft power. — Optional (one per pressure level)
Total head — m — Positive. — Required (when pressure rise given by = total head)
Maximum mass flow — kg/s — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Maximum shaft power — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Work — W — Negative (work into the fluid).
Shaft power — W — The power taken from the shaft (positive); only when the shaft input is fixed.
Electric power — W — The electric input; only with an overall efficiency or electric input.
Water power — W — \dot m v_1 (p_2-p_1).
Overall efficiency — − — Water power ÷ electric input; only with an overall efficiency or electric input.
Isentropic efficiency — − — From the states (water side); not with all losses to the surroundings (1 by that assumption).
Pump efficiency — − — From the states (water side); reported like the isentropic efficiency.
Automatic conversions — − / W — Pump efficiency = overall ÷ motor efficiency; shaft input = electric input × motor efficiency.
Total head — m — From the states, whichever way the pump was specified.
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum mass flow, maximum shaft power) — − — Required value ÷ the maximum entered; only when entered.
System: pump and compressor shaft power — W — Added to the system indicator.
↑ Contents

### Compressor block
- Represents: an adiabatic machine that raises the pressure of a gas. Losses make the outlet hotter than the ideal one. Used in refrigeration and Brayton cycles.
- Ports: inlet and outlet (working fluid, required), shaft (input, optional). A compressor given by its electric input includes its motor and has no shaft connection.
- Checks: an outlet pressure not above the inlet is an error. Liquid at the inlet (wet compression) is warned. A shaft or electric input below what a loss-free compression needs is an error.

Inputs
Quantity — Unit — Description — Required / optional
Performance model (fixed / public generic map / user map) and the map settings — (choice) — With a map, the efficiency and pressure ratio (turbine: flow) follow from the map at each operating point and the fixed-efficiency settings do not apply. Design point, speed and the other settings: see compressor and turbine maps. Used for: off-design (part-load) operating points. — Optional (default fixed)
Performance given by — (choice) — Isentropic efficiency / polytropic efficiency / shaft input / electric input. Used for: Chooses which field gives the outlet state and the power; only the chosen method's fields are used. — Optional (default isentropic efficiency)
Isentropic efficiency — − — Loss-free compression work ÷ actual work. Above 0, at most 1; initial value 0.8. — Required (isentropic efficiency)
Polytropic efficiency — − — The small-stage efficiency \eta_p = v\,dp/dh. Above 0, at most 1. Converted to the isentropic efficiency at the operating point. — Required (polytropic efficiency)
Shaft input — W — Positive; all of it goes into the fluid. — Required (shaft input)
Electric input — W — With the motor. Positive. — Required (electric input)
Where the losses go — (choice) — All warm the fluid / split with a motor efficiency. Used for: The assumption for the outlet state; unless split, no shaft input is reported. — Required (electric input)
Motor efficiency (shaft output ÷ electric input) — − — Above 0, at most 1. Used for: Shaft input = electric input × motor efficiency. — Required (when split with a motor efficiency)
Pressure rise given by — (choice) — Discharge pressure / pressure ratio. Used for: Chooses whether the discharge pressure or the pressure ratio sets the outlet pressure. — Optional (default discharge pressure)
Discharge pressure — Pa — The outlet pressure. Not together with a pressure ratio. Used for: Sets the pressure of the outlet pressure level. As the pressure rise, it is used for the outlet state and the compressor's shaft power. — Optional (one per pressure level)
Pressure ratio (outlet / inlet) — − — Above 1. — Required (when pressure rise given by = pressure ratio)
Maximum mass flow — kg/s — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Maximum shaft power — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Work — W — Negative (work into the fluid).
Shaft power — W — The power taken from the shaft (positive); only when the shaft input is fixed.
Electric power — W — The electric input; only when given by it.
Isentropic efficiency — − — From the states.
Automatic conversions — − / W — The isentropic efficiency converted from the polytropic one at the operating point; shaft input = electric input × motor efficiency.
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum mass flow, maximum shaft power) — − — Required value ÷ the maximum entered; only when entered.
System: pump and compressor shaft power — W — Added to the system indicator.
↑ Contents

### Turbine block
- Represents: a machine that expands the working fluid adiabatically and takes work out.
- Ports: inlet and outlet (working fluid, required), shaft (output, optional). The shaft can go both to a generator and to pumps or compressors it drives directly.
- Directly driven pumps: their power is taken off this turbine's shaft before the generator. Shaft power left over with no generator connected is warned.
- Extraction: the turbine has no extraction port. Represent extraction by two turbines with a splitter between them.
- Checks: an outlet pressure not below the inlet is an error. An exhaust quality below the minimum is warned; the results are not changed.

Inputs
Quantity — Unit — Description — Required / optional
Performance model (fixed / public generic map / user map) and the map settings — (choice) — With a map, the efficiency and pressure ratio (turbine: flow) follow from the map at each operating point and the fixed-efficiency settings do not apply. Design point, speed and the other settings: see compressor and turbine maps. Used for: off-design (part-load) operating points. — Optional (default fixed)
Performance given by — (choice) — Isentropic efficiency / shaft output ÷ loss-free expansion power / shaft output. Used for: Chooses which field gives the outlet state and the shaft output. Check what a “turbine efficiency” in your source means before choosing. — Optional (default isentropic efficiency)
Isentropic efficiency — − — Work done by the fluid ÷ loss-free expansion work; no mechanical loss included. Above 0, at most 1; initial value 0.85. — Required (isentropic efficiency)
Shaft output ÷ loss-free expansion power — − — P_{\mathrm{shaft}}/[\dot m (h_1-h_{2s})]; includes mechanical losses. Above 0, at most 1. — Required (this ratio)
Shaft output — W — Positive; the efficiency is a result. — Required (shaft output)
Where the losses go — (choice) — Ratio: all stay in the fluid (no mechanical loss) / all outside the fluid (loss-free expansion) / split with a mechanical efficiency. Shaft output: no mechanical loss / split with a mechanical efficiency. Used for: The assumption for the outlet state; the shaft output is the same, the exhaust temperature and quality change. — Required (ratio or shaft output)
Exhaust pressure — Pa — The outlet pressure. Leave it blank when another field on the outlet level sets it, such as the condenser's condensing pressure. Used for: Sets the pressure of the exhaust pressure level. As the end pressure of the expansion, it is used for the exhaust state and the turbine's work. — Optional (one per pressure level)
Mechanical efficiency (shaft output ÷ work done by the fluid) — − — Above 0, at most 1. Optional with the isentropic efficiency (blank means 1, no mechanical loss); required when splitting the losses with it. Used for: The share of the steam's work that reaches the shaft. Shaft output = steam work × mechanical efficiency and mechanical loss = the difference; the shaft output is used for the net shaft output, the generator's input and any pump driven directly. — Optional
Minimum exhaust quality — − — 0 to 1. A check only; does not change the operating point. Blank means not checked. Used for: Used for the physical-condition check: a warning when the exhaust quality is below this value. — Optional
Maximum mass flow — kg/s — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Maximum shaft power — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Work — W — Positive (work done by the fluid).
Shaft power — W — Shaft output = work × mechanical efficiency.
Mechanical loss — W — Work − shaft output.
Isentropic efficiency — − — From the states.
Shaft output ÷ loss-free expansion power — − — Isentropic × mechanical efficiency.
Loss-free expansion power — W — \dot m (h_1-h_{2s}).
Mechanical efficiency (used) — − —
Automatic conversions — − / W — Isentropic and mechanical efficiencies converted from the ratio; work done by the fluid = shaft output ÷ mechanical efficiency.
Outlet connection state — (common table) — The quantities of the common table (the exhaust quality included).
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum mass flow, maximum shaft power) — − — Required value ÷ the maximum entered; only when entered.
System: turbine shaft output — W — Added to the system indicator.
↑ Contents

## Blocks that exchange heat with the outside
The next four are the same model. You give the outlet state, and the heat needed to reach it, \dot Q = \dot m (h_2 - h_1), is calculated. The heat comes from (or goes to) outside the system; the temperature of a heat source or sink and the heat transfer surface are not modelled. They differ in which result indicator counts the heat. The pressure drop is always the difference between inlet and outlet pressure, and the outlet pressure is given as the pressure condition of its level.

### Boiler / heater block
- Represents: equipment that heats, boils and superheats the working fluid. Fuel combustion, the furnace and the tubes are not modelled.
- Ports: inlet and outlet (working fluid, required).
- Counted as: the heat added is counted in the “heat input to the working fluid”, the denominator of the cycle thermal efficiency. With a boiler efficiency and a heating value basis, fuel heat input = heat to the working fluid ÷ boiler efficiency gives a fuel-based generation efficiency. It is given only when every boiler / heater and reheater adding heat has a boiler efficiency and they share one basis.

Inputs
Quantity — Unit — Description — Required / optional
Outlet state given by — (choice) — Outlet temperature / outlet quality / heat to the working fluid. Used for: Chooses which field fixes the outlet state. Only the chosen field is used. — Optional (default outlet temperature)
Heat to the working fluid (effective heat) — W — Positive; not the fuel heat input. The outlet state follows from the heat balance. — Required (when given by the heat)
Outlet temperature — K — Initial value 773.15 K (500 °C). — Required (when outlet state given by = outlet temperature)
Outlet quality — − — 0 to 1; initial value 1 (saturated vapour). — Required (when outlet state given by = outlet quality)
Outlet pressure — Pa — Leave it blank when another field on the same level sets it, such as the pump's discharge pressure. Used for: Sets the pressure of this pressure level (the part joined by equipment that does not change the pressure). It is used for the outlet state and the heat added or removed. — Optional (one per pressure level)
Pressure drop — Pa — Inlet minus outlet pressure (advanced). At least 0. Used for: Links the inlet and outlet pressures (outlet = inlet − pressure drop). It affects the outlet state and the pressures of the equipment before and after. — Optional (default 0 Pa)
Fuel given by — (choice) — No fuel / boiler efficiency / fuel heat input (advanced). A heater saved earlier with a boiler efficiency is read as the boiler efficiency. Used for: How the fuel heat input is found: the target of a fuel heat input purpose, and the denominator of the generating efficiency (net electric output ÷ fuel heat input). Given only when every heater adding heat inside the evaluation boundary has it. — Optional (default no fuel; the boiler efficiency is required when this block is a chosen heater of a fuel heat input target)
Boiler efficiency (heat to the working fluid ÷ fuel heat input) — − — Above 0, at most 1. Fuel heat input = heat ÷ boiler efficiency. — Required (boiler efficiency)
Fuel heat input — W — Fuel flow × heating value. Positive. The boiler efficiency = heat ÷ fuel heat input is a result. Below the heat on the HHV basis is an error; on the LHV basis a warning. — Required (fuel heat input)
Heating value basis — (choice) — HHV / LHV (advanced). Used for: Records which heating value the fuel heat input and the generating efficiency are based on; it does not change the computed values. Different bases on different heaters give no fuel heat input; a comparison of cases warns when they differ. Without it no fuel heat input is reported. — Required with a fuel heat input; optional with a boiler efficiency
Maximum heat duty — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Maximum steam flow — kg/s — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat — W — Positive (heat into the working fluid).
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum heat duty, maximum steam flow) — − — Required value ÷ the maximum entered; only when entered.
System: heat input to the working fluid — W — Added to the system indicator.
Fuel heat input — W — This block's fuel heat input; only with a fuel and a heating value basis.
Automatic conversions — − / W — The boiler efficiency from the fuel heat input, or the fuel heat input from the boiler efficiency.
System: fuel heat input — W — The heaters' sum; only when every heater has one and the bases agree.
↑ Contents

### Reheater block
- Represents: equipment between turbine stages that heats the expanded steam again.
- Model: the same settings and calculation as the boiler / heater. It is a separate type only so the block list and the results name it.
- Ports: inlet and outlet (working fluid, required).
- Counted as: its heat is counted in the “heat input to the working fluid”.

Inputs
Quantity — Unit — Description — Required / optional
Outlet state given by — (choice) — Outlet temperature / outlet quality / heat to the working fluid. Used for: Chooses which field fixes the outlet state. Only the chosen field is used. — Optional (default outlet temperature)
Heat to the working fluid (effective heat) — W — Positive; not the fuel heat input. The outlet state follows from the heat balance. — Required (when given by the heat)
Outlet temperature — K — Initial value 773.15 K (500 °C). — Required (when outlet state given by = outlet temperature)
Outlet quality — − — 0 to 1; initial value 1. — Required (when outlet state given by = outlet quality)
Outlet pressure — Pa — Leave it blank when another field on the same level sets it, such as the exhaust pressure of the turbine before it. Used for: Sets the pressure of this pressure level (the part joined by equipment that does not change the pressure). It is used for the outlet state and the heat added or removed. — Optional (one per pressure level)
Pressure drop — Pa — Inlet minus outlet pressure (advanced). At least 0. Used for: Links the inlet and outlet pressures (outlet = inlet − pressure drop). It affects the outlet state and the pressures of the equipment before and after. — Optional (default 0 Pa)
Fuel given by — (choice) — No fuel / boiler efficiency / fuel heat input (advanced). A heater saved earlier with a boiler efficiency is read as the boiler efficiency. Used for: How the fuel heat input is found: the target of a fuel heat input purpose, and the denominator of the generating efficiency (net electric output ÷ fuel heat input). Given only when every heater adding heat inside the evaluation boundary has it. — Optional (default no fuel; the boiler efficiency is required when this block is a chosen heater of a fuel heat input target)
Boiler efficiency (heat to the working fluid ÷ fuel heat input) — − — Above 0, at most 1. Fuel heat input = heat ÷ boiler efficiency. — Required (boiler efficiency)
Fuel heat input — W — Fuel flow × heating value. Positive. The boiler efficiency = heat ÷ fuel heat input is a result. Below the heat on the HHV basis is an error; on the LHV basis a warning. — Required (fuel heat input)
Heating value basis — (choice) — HHV / LHV (advanced). Used for: Records which heating value the fuel heat input and the generating efficiency are based on; it does not change the computed values. Different bases on different heaters give no fuel heat input; a comparison of cases warns when they differ. Without it no fuel heat input is reported. — Required with a fuel heat input; optional with a boiler efficiency
Maximum heat duty — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Maximum steam flow — kg/s — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat — W — Positive (heat into the working fluid).
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum heat duty, maximum steam flow) — − — Required value ÷ the maximum entered; only when entered.
System: heat input to the working fluid — W — Added to the system indicator.
Fuel heat input — W — This block's fuel heat input; only with a fuel and a heating value basis.
Automatic conversions — − / W — The boiler efficiency from the fuel heat input, or the fuel heat input from the boiler efficiency.
System: fuel heat input — W — The heaters' sum; only when every heater has one and the bases agree.
↑ Contents

### Cooler (heat rejection) block
- Represents: equipment that cools the working fluid without condensing it and rejects the heat to the outside.
- Ports: inlet and outlet (working fluid, required).
- Counted as: the heat removed is counted in the “heat rejected”.
- Typical use: in an air-standard Brayton cycle it stands for discharging the exhaust to the atmosphere and drawing in fresh air. Real plants need not have such a device.

Inputs
Quantity — Unit — Description — Required / optional
Outlet state given by — (choice) — Outlet temperature / outlet quality. Used for: Chooses whether the outlet temperature or the outlet quality fixes the outlet state. Only the chosen field is used. — Optional (default outlet temperature)
Outlet temperature — K — Initial value 300 K. — Required (when outlet state given by = outlet temperature)
Outlet quality — − — 0 to 1; initial value 1. — Required (when outlet state given by = outlet quality)
Outlet pressure — Pa — Leave it blank when another field on the same level sets it. Used for: Sets the pressure of this pressure level (the part joined by equipment that does not change the pressure). It is used for the outlet state and the heat added or removed. — Optional (one per pressure level)
Pressure drop — Pa — Inlet minus outlet pressure (advanced). At least 0. Used for: Links the inlet and outlet pressures (outlet = inlet − pressure drop). It affects the outlet state and the pressures of the equipment before and after. — Optional (default 0 Pa)
Maximum heat removal — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat — W — Negative (heat removed from the working fluid).
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum heat removal) — − — Required value ÷ the maximum entered; only when entered.
System: heat rejected — W — Added to the system indicator.
↑ Contents

### Evaporator block
- Represents: in a refrigeration cycle, the equipment where the refrigerant boils by taking heat from the space being cooled.
- Ports: inlet and outlet (working fluid, required).
- Counted as: the heat taken in is counted as the “refrigeration effect”, not as heat input. The coefficients of performance are COP_cooling = refrigeration effect ÷ net shaft power consumed and COP_heating = heat rejected ÷ the same power.

Inputs
Quantity — Unit — Description — Required / optional
Outlet state given by — (choice) — Outlet temperature / outlet quality. Used for: Chooses whether the outlet temperature or the outlet quality fixes the outlet state. Only the chosen field is used. — Optional (default outlet temperature)
Outlet temperature — K — No initial value. — Required (when outlet state given by = outlet temperature)
Outlet quality — − — 0 to 1; initial value 1 (saturated vapour). — Required (when outlet state given by = outlet quality)
Outlet pressure — Pa — Leave it blank when another field on the same level sets it, such as the expansion valve's outlet pressure. Used for: Sets the pressure of this pressure level (the part joined by equipment that does not change the pressure). It is used for the outlet state and the heat added or removed. — Optional (one per pressure level)
Pressure drop — Pa — Inlet minus outlet pressure (advanced). At least 0. Used for: Links the inlet and outlet pressures (outlet = inlet − pressure drop). It affects the outlet state and the pressures of the equipment before and after. — Optional (default 0 Pa)
Maximum refrigeration duty — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat — W — Positive (heat into the working fluid).
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum refrigeration duty) — − — Required value ÷ the maximum entered; only when entered.
System: refrigeration effect — W — Added to the system indicator.
System: COP (refrigeration / cooling), COP (heat pump / heating) — − — Only for a cycle that consumes net shaft power.
↑ Contents

## Condensing and heat exchange
### Condenser block
- Represents: equipment that cools the vapour leaving the turbine (or the compressor of a refrigerator) back to liquid. The heat removed is counted in the “heat rejected”. Only for condensing fluids (water, R134a).
- Outlet state: set by the condensing pressure (the outlet value) and the subcooling. Subcooling 0 means saturated liquid (quality 0).
- Simple model: no cooling water is drawn; the heat leaves the system.
- Detailed model: cooling water inlet and outlet ports appear and the condenser exchanges heat with the cooling water in counter-flow (water cycles only). Choose one cooling-side condition; with anything but the condensing pressure, leave the pressure blank and the heat transfer condition sets it.
- Ports: inlet and outlet (working fluid, required); with the detailed model, cooling water inlet and outlet (required).
- Checks: the minimum temperature difference is reported from the solver and also found independently by dividing both sides into segments. A temperature cross (minimum difference 0 or below) is an error.

Inputs
Quantity — Unit — Description — Required / optional
Model — (choice) — Simple / detailed. Used for: Chooses the simple model (condensing pressure and subcooling only) or the detailed one (cooling water and a heat transfer condition as well). The cooling water fields are used only with the detailed model. — Optional (default simple)
Condensing pressure (outlet, absolute) — Pa — Simple model: leave it blank when another field on the same level sets it, such as the turbine's exhaust pressure. Detailed model: enter it only when heat transfer given by = condensing pressure; otherwise leave it blank. Used for: Sets the condensing pressure. It fixes the condensing temperature (the saturation temperature at that pressure) and the exhaust pressure of the turbine on the same level. — Optional (simple model: one per pressure level; detailed model: required when heat transfer given by = condensing pressure)
Outlet subcooling — K — 0 K = saturated liquid. At least 0. Used for: How many K the outlet water is cooled below the saturation temperature. It affects the outlet state, the heat removed in the condenser and the state at the next pump's inlet. — Optional (default 0 K)
Heat transfer given by — (choice) — UA / minimum temperature difference / cooling water outlet temperature / condensing pressure. — Required (when model = detailed; default UA)
UA (overall conductance) — W/K — Positive. — Required (detailed model, when heat transfer given by = UA)
Minimum temperature difference — K — Positive. — Required (detailed model, when heat transfer given by = minimum temperature difference)
Cooling water outlet temperature — K — — Required (detailed model, when heat transfer given by = cooling water outlet temperature)
Pressure drop (steam side) — Pa — Inlet minus outlet pressure on the working fluid side (advanced). At least 0. Used for: Links the inlet and outlet pressures on the working fluid side (outlet = inlet − pressure drop). — Optional (default 0 Pa)
Pressure drop (cooling water side) — Pa — Used with the detailed model (advanced). At least 0. Used for: Used for the cooling water's outlet state (outlet pressure = inlet pressure − pressure drop). — Optional (default 0 Pa)
Maximum heat removal — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat — W — Simple model. Negative (heat removed from the working fluid).
Heat exchanged — W — Detailed model. Heat from the working fluid to the cooling water.
UA — W/K — Detailed model.
Minimum temperature difference (sectioned check) — K — Detailed model. Found by dividing both sides into segments.
Minimum temperature difference (solver) — K — Detailed model, when the solver returns it.
Outlet connection state — (common table) — The quantities of the common table; with the detailed model also on the cooling water outlet line.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum heat removal) — − — Required value ÷ the maximum entered; only when entered.
System: heat rejected — W — Added to the system indicator.
↑ Contents

### Heat exchanger (two fluids) block
- Represents: equipment that moves heat between two streams, such as a closed feedwater heater (feedwater warmed by extraction steam) or the regenerator of a Brayton cycle. The heat stays inside the system, so it is counted neither as heat input nor as heat rejected.
- Ports: hot inlet, hot outlet, cold inlet, cold outlet (all working fluid, required).
- Model: solved zone by zone (liquid, two-phase, vapour), so the minimum temperature difference inside is found even with condensation or boiling, not only at the ends. Given UA, it is first solved with a provisional condition (minimum difference 10 K) and then re-solved with your UA from that point; the result satisfies your UA.
- Checks: a temperature cross is an error. A difference below the “required minimum temperature difference” is warned; the operating point is not changed.

Inputs
Quantity — Unit — Description — Required / optional
Flow arrangement — (choice) — Counter-flow only. Used for: Chooses the equations of a flow arrangement. Only counter-flow exists now, so the calculation always uses the counter-flow equations. — Optional (default counter-flow)
Heat transfer given by — (choice) — UA / effectiveness / minimum temperature difference / hot or cold side outlet temperature / heat duty. Used for: Chooses which field fixes the heat exchanged. Only the chosen field is used. — Optional (default UA)
UA (overall conductance) — W/K — Positive. — Required (when heat transfer given by = UA)
Effectiveness ε — − — Heat exchanged ÷ the largest possible: the smaller of the hot side cooled to the cold inlet temperature and the cold side heated to the hot inlet temperature (by enthalpies, so phase change is covered). Above 0, below 1. Solved like UA from a provisional condition. — Required (effectiveness)
Minimum temperature difference — K — Positive. — Required (when heat transfer given by = minimum temperature difference)
Hot side outlet temperature — K — — Required (when heat transfer given by = hot side outlet temperature)
Cold side outlet temperature — K — — Required (when heat transfer given by = cold side outlet temperature)
Heat duty — W — Positive. — Required (when heat transfer given by = heat duty)
Pressure drop (hot side) — Pa — Advanced. At least 0. Used for: Used for the hot side's outlet state (outlet pressure = inlet pressure − pressure drop). — Optional (default 0 Pa)
Pressure drop (cold side) — Pa — Advanced. At least 0. Used for: Used for the cold side's outlet state (outlet pressure = inlet pressure − pressure drop). — Optional (default 0 Pa)
Required minimum temperature difference — K — A check only; does not change the operating point. At least 0. Blank means not checked. Used for: Used for the physical-condition check: a warning when the computed minimum temperature difference is below this value. — Optional
Maximum heat duty — W — Capability; does not change the operating point. Used for: Used for the capability check: the operating value ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Heat exchanged — W — Heat from the hot to the cold side.
UA — W/K —
Effectiveness ε — − — From the states, whichever way it was given.
Minimum temperature difference (sectioned check) — K — Found by dividing both sides into segments.
Minimum temperature difference (solver) — K — When the solver returns it.
Hot and cold outlet connection states — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
Utilisation (maximum heat duty) — − — Required value ÷ the maximum entered; only when entered.
↑ Contents

## Blocks that change the flow
### Pipe block
- Represents: piping between equipment, as a box with a pressure drop and a heat loss to the surroundings.
- Ports: inlet and outlet (working fluid, required).
- Counted as: the heat loss is shown as “pipe heat loss”, separately from the heat rejected.
- Note: the pressure drop is not calculated from the diameter, length or roughness. That is the Engineering CAD's straight pipe block.

Inputs
Quantity — Unit — Description — Required / optional
Pressure drop — Pa — Inlet minus outlet pressure. At least 0. Used for: Used for the outlet state (outlet pressure = inlet pressure − pressure drop). — Optional (default 0 Pa)
Heat loss to the surroundings (negative = gained) — W — Positive = lost to the surroundings, negative = gained. With the pressure drop also 0, the pipe is adiabatic with no pressure drop. Used for: Used for the outlet's specific enthalpy (lower by the heat lost). It is also counted in the system's pipe heat loss. — Optional (default 0 W)
Outputs
Quantity — Unit — Description
Heat — W — The heat loss with its sign reversed (negative for a loss).
Outlet connection state — (common table) — The quantities of the common table.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
System: pipe heat loss — W — Added to the system indicator.
↑ Contents

### Throttle valve block
- Represents: a valve that lowers the pressure by narrowing the flow; also the expansion valve of a refrigerator.
- Model: no work and no heat, so the specific enthalpy does not change (isenthalpic). As the pressure falls, part of the liquid may evaporate and the temperature may fall. The entropy rises. Valve opening and flow coefficients (Cv, Kv) are not modelled.
- Ports: inlet and outlet (working fluid, required).

Inputs
Quantity — Unit — Description — Required / optional
Outlet pressure — Pa — Leave it blank when another field on the outlet level sets it, such as the evaporator's outlet pressure. Used for: Sets the pressure of the outlet pressure level. It is used for the state after throttling (constant specific enthalpy). — Optional (one per pressure level)
Outputs
Quantity — Unit — Description
Outlet connection state — (common table) — The quantities of the common table (the temperature and quality after the pressure drop). No heat or work (both 0).
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
↑ Contents

### Splitter (extraction) block
- Represents: divides one stream into 2–4. Every outlet has the inlet's pressure and specific enthalpy; only the mass flow is divided.
- Ports: inlet, outlets 1 to n (n = number of outlets; all working fluid, required).
- Typical use: between two turbine stages it is an extraction (steam bled part-way through the turbine).
- Setting the fractions: the last outlet (outlet n) takes the rest, so fractions are given for outlets 1 to n−1. A fraction left blank must be set by another condition (such as a merge's “outlet is saturated liquid”); otherwise the conditions are insufficient.

Inputs
Quantity — Unit — Description — Required / optional
Number of outlets — − — 2 to 4. Used for: Sets how many outlet ports there are. — Optional (default 2)
Fraction of the inlet flow to outlet 1 — − — A fraction of the inlet mass flow. Above 0 and below 1. Used for: Splits the flow: outlet 1's mass flow = fraction × inlet mass flow. — Optional (blank: another condition must set it)
Fraction of the inlet flow to outlet 2 — − — Used only with 3 or more outlets (ignored with 2). Used for: Splits the flow: outlet 2's mass flow = fraction × inlet mass flow. — Optional (blank: another condition must set it)
Fraction of the inlet flow to outlet 3 — − — Used only with 4 outlets. Used for: Splits the flow: outlet 3's mass flow = fraction × inlet mass flow. — Optional (blank: another condition must set it)
Outputs
Quantity — Unit — Description
Each outlet connection state — (common table) — The quantities of the common table (the mass flow shows the split). No heat or work.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
↑ Contents

### Merge / open feedwater heater block
- Represents: adiabatic mixing of 2–4 streams. Mass and energy are conserved; the outlet's specific enthalpy is the mass-flow-weighted mean of the inlets'.
- Pressure: all inlets and the outlet are on one pressure level. Condensate, for example, is pumped up to the extraction pressure before it joins.
- Ports: inlets 1 to n (n = number of inlets), outlet (all working fluid, required).

Inputs
Quantity — Unit — Description — Required / optional
Number of inlets — − — 2 to 4. Used for: Sets how many inlet ports there are. — Optional (default 2)
Outlet is saturated liquid (open feedwater heater / deaerator) — (on/off) — When on, the extraction flow is found so that the outlet is exactly saturated liquid (quality 0); leave the fraction of the splitter making that extraction blank. Used for: Used as the condition that fixes the extraction flow. When off, the outlet state is simply the result of mixing the inlet flows. — Optional (default off)
Outputs
Quantity — Unit — Description
Outlet connection state — (common table) — The quantities of the common table. No heat or work.
Energy residual — W — The residual of this block's energy balance.
Energy residual (relative) — − — Residual ÷ the size of the energy flows.
Mass residual — kg/s — The residual of this block's mass balance.
↑ Contents

## Power and electricity blocks
They do not enter the fluid equations: their efficiencies act on shaft power after the fluid solution. Their efficiencies therefore do not affect the fluid calculation, except with a net electric output target: the flow is then found again to meet the electric output, so the flow changes. Generators and motors have no connection states and no balance residuals.

### Generator block
- Represents: equipment that turns turbine shaft power into electricity. The net electric output and the generation efficiency are given only when there is a generator.
- Conversion: electric output = shaft input × efficiency. The shaft input is the connected turbines' shaft output minus the power of pumps they drive directly.
- Port: shaft (input, required; it accepts several turbines).

Inputs
Quantity — Unit — Description — Required / optional
Efficiency given by — (choice) — Conversion efficiency / data point input and output. Used for: Enter the efficiency, or one input and output pair from a test report (efficiency = output ÷ input). — Optional (default conversion efficiency)
Conversion efficiency (electric output ÷ shaft input) — − — Above 0, at most 1; initial value 0.98. — Required (conversion efficiency)
Shaft input and electric output at the data point — W — Positive; the output not above the input. The efficiency is assumed constant; a note gives the operating shaft input relative to the data point. — Required (data point)
Rated output — W — Capability, compared with the electric output; does not change the operating point. Used for: Used for the capability check: the electric output ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Shaft power — W — The shaft input received.
Electric power — W — The electric output.
Conversion loss — W — Shaft input − electric output.
Automatic conversions — − — The conversion efficiency from the data point.
Utilisation (rated output) — − — Electric output ÷ rated output; only when entered.
System: net electric output — W — Generator output − motors' electric input − electric input of pumps and compressors given with their motor − other auxiliary power.
System: generation efficiency — − — Net electric output ÷ fuel heat input; only when the fuel heat input is known.
↑ Contents

### Motor block
- Represents: equipment that drives a pump or compressor with electricity; one motor drives one pump or compressor.
- Conversion: electric input = shaft output ÷ efficiency. The net electric output is the generator output minus the motors' electric input and the other auxiliary power (a system condition).
- Port: shaft (output, required).

Inputs
Quantity — Unit — Description — Required / optional
Efficiency given by — (choice) — Conversion efficiency / data point input and output. Used for: Enter the efficiency, or one input and output pair from a catalogue (efficiency = output ÷ input). — Optional (default conversion efficiency)
Conversion efficiency (shaft output ÷ electric input) — − — Above 0, at most 1; initial value 0.95. — Required (conversion efficiency)
Electric input and shaft output at the data point — W — Positive; the output not above the input. Assumed constant; a note gives the operating point relative to the data point. — Required (data point)
Maximum input power — W — Capability, compared with the electric input; does not change the operating point. Used for: Used for the capability check: the electric input ÷ this value is shown as the usage, and any shortfall is shown. — Optional
Outputs
Quantity — Unit — Description
Shaft power — W — The shaft output given to the pump or compressor.
Electric power — W — The electric input.
Conversion loss — W — Electric input − shaft output.
Automatic conversions — − — The conversion efficiency from the data point.
Utilisation (maximum input power) — − — Electric input ÷ maximum input power; only when entered.
↑ Contents

## Cooling water blocks
### Cooling water inlet block
- Represents: the boundary where cooling water enters a detailed condenser (water cycles only).
- Port: outlet (cooling water, required).

Inputs
Quantity — Unit — Description — Required / optional
Pressure (absolute) — Pa — Initial value 2.0×10⁵ Pa (200 kPa). — Required
Temperature — K — Initial value 293.15 K (20 °C). — Required
Mass flow — kg/s — Positive. Left blank, it follows from another condition such as the condenser's cooling water outlet temperature. Used for: As the cooling water flow, it is used with the condenser's heat balance (heat removed = cooling water flow × rise in specific enthalpy) to find the cooling water outlet temperature. — Optional
Outputs
Quantity — Unit — Description
Outlet connection state — (common table) — The cooling water's mass flow, pressure, temperature, specific enthalpy, specific entropy, specific volume, phase. No balance residuals.
↑ Contents

### Cooling water outlet block
- Represents: the boundary where the cooling water leaves the system.
- Port: inlet (cooling water, required).
- Inputs: none.
- Outputs: the block itself has none. Read the cooling water's outlet temperature and flow at the state point of the connecting line (the items of the common table).

↑ Contents

## Energy and mass balance of a block
R_E = \sum_{\mathrm{in}} \dot m h - \sum_{\mathrm{out}} \dot m h + \dot Q - \dot W, \qquad R_m = \sum_{\mathrm{in}} \dot m - \sum_{\mathrm{out}} \dot m
A balance passes when |R| \le absolute tolerance + relative tolerance × max(in, out, floor) (rule tc-balance-1).
## Rotating machines (1: inlet, 2: outlet, 2s: isentropic change to the same outlet pressure)
\eta_{s,\mathrm{pump/compressor}} = \frac{h_{2s} - h_1}{h_2 - h_1}, \qquad \eta_{s,\mathrm{turbine}} = \frac{h_1 - h_2}{h_1 - h_{2s}}
\eta_{\mathrm{pump}} = \frac{v_1 (p_2 - p_1)}{h_2 - h_1}, \qquad H = \frac{(p_2 - p_1)\, v_1}{g}, \quad g = 9.80665\ \mathrm{m/s^2}
\dot W_{\mathrm{shaft,turbine}} = \eta_{\mathrm{m}}\, \dot m (h_1 - h_2), \qquad \dot W_{\mathrm{shaft,pump}} = \dot m (h_2 - h_1)
## Blocks exchanging heat with the outside, and the pipe
\dot Q = \dot m (h_2 - h_1), \qquad p_2 = p_1 - \Delta p
For a pipe \dot Q = -(heat loss). Fuel heat input \dot Q_{\mathrm{fuel}} = \dot Q / \eta_{\mathrm{B}} (\eta_{\mathrm{B}}: boiler efficiency).
## Two-fluid heat exchanger and detailed condenser
\dot Q = \dot m_{\mathrm{h}} (h_{\mathrm{h,in}} - h_{\mathrm{h,out}}) = \dot m_{\mathrm{c}} (h_{\mathrm{c,out}} - h_{\mathrm{c,in}})
Given UA, TESPy's MovingBoundaryHeatExchanger uses a log-mean temperature difference in each phase zone and finds the operating point where the zones' UA add up to the given value.
## Throttle valve, splitter, merge
h_2 = h_1 \ (\mathrm{valve}), \qquad \dot m_k = f_k \dot m_1,\ p_k = p_1,\ h_k = h_1 \ (\mathrm{splitter}), \qquad \dot m_{\mathrm{out}} h_{\mathrm{out}} = \sum_i \dot m_i h_i,\ p_i = p_{\mathrm{out}} \ (\mathrm{merge})
## Generator and motor
P_{\mathrm{el,generator}} = \eta_{\mathrm{g}}\, P_{\mathrm{shaft}}, \qquad P_{\mathrm{el,motor}} = P_{\mathrm{shaft}} / \eta_{\mathrm{mot}}
## How it is calculated
The blocks become TESPy 0.11.3 components and the whole cycle is solved simultaneously. Properties come from CoolProp 8.0.0.
- pump → Pump, compressor → Compressor, turbine → Turbine, throttle valve → Valve
- boiler / heater, reheater, cooler, evaporator, simple condenser, pipe → SimpleHeatExchanger
- two-fluid heat exchanger, detailed condenser → MovingBoundaryHeatExchanger
- splitter → Splitter, merge → Merge, cooling water inlet / outlet → Source / Sink
- the generator and motor are not TESPy components.

- Steady design-point calculations only. Start-up, shut-down and other changes over time, and part load (operation along equipment characteristics), are not covered.
- The boiler / heater does not model combustion. The composition of air in a gas cycle is fixed; changes due to combustion are not modelled.
- Heat source and heat sink blocks with heat lines, and parallel-flow heat exchangers, are not implemented.
- Capability / limit fields are checks only; the operating point is never adjusted to them.
- The reference state of enthalpy and entropy differs between working fluids, so do not compare values across results of different fluids.
- This page is revised whenever the calculation definitions change.