Using the Thermal Cycle CAD and what it assumes — 3 / 12
Entering conditions and calculating
The four machines joined in part 2 get the boiler's outlet pressure and temperature, the turbine's and pump's efficiencies and the condenser's pressure, the cycle's flow is set to 10 kg/s, and the cycle is calculated. The part explains why the turbine and pump get no outlet pressure (pressure regions), why the flow is given in one place only, and what the console says when something is deliberately wrong.
Joining the machines does not yet decide at what pressures and temperatures the water goes round, or how much of it flows. To calculate, each machine needs conditions — how hot the boiler makes the steam, how good the turbine is, and so on.
What matters is to enter the conditions that are needed, and as many as are needed. Too few and the answer is not fixed; too many and conditions may contradict each other. The Thermal Cycle CAD checks the number of conditions at every edit and reports in the console at the bottom.
## Just like simultaneous equations
In simultaneous equations, two unknowns need two equations. With only one equation the answer is not fixed, and two equations that say the same thing do not fix it either. Conversely, three equations that contradict each other have no answer.
Calculating a thermal cycle is the same: the pressures, temperatures and flows of the lines (state points) are the unknowns; the machines' behaviour and the entered conditions are the equations. The Thermal Cycle CAD asks for conditions so that the numbers of unknowns and equations match exactly.
## A hose made into a ring
When water goes round a hose made into a ring, the amount flowing per second is the same wherever you measure it (water neither appears nor vanishes on the way). So the flow given at one place in the ring fixes it on every line. Giving it at two places says the same thing twice.
## The conditions to enter
Enter these conditions in the cycle joined in part 2. They are the values of the tutorial “Simple Rankine”.
Machine — Field — Value
Boiler / heater — outlet pressure — 10 MPa
Boiler / heater — outlet temperature — 500 °C
Turbine — isentropic efficiency — 0.9
Condenser — condensing pressure — 10 kPa
Condenser — outlet subcooling — 0 K
Pump — isentropic efficiency — 0.75
Whole system — mass flow (state point ②) — 10 kg/s
## Step 1: boiler / heater
Press the boiler / heater on the canvas; its settings appear on the right.
1. Leave “Outlet state given by” at “Outlet temperature”.
2. “Outlet temperature” already holds 500 °C (773.15 K). Leave it.
3. Set the unit of “Outlet pressure (absolute, optional)” to MPa and enter 10.
Each number field has a unit selector next to it; entered values are converted to SI units (Pa, K, …) automatically before the calculation. The ? next to a field explains what it means and its formula.
## Step 2: turbine
1. Leave “Performance given by” at “Isentropic efficiency”.
2. Change “Isentropic efficiency” from 0.85 to 0.9.
3. Leave “Exhaust pressure (absolute, optional)” empty (the reason is under “Pressure regions” below).
The isentropic efficiency says what fraction of the work of a perfect, loss-free turbine the real turbine delivers (0.9 means 90 %).
## Step 3: condenser
1. Leave “Model” at “Simple (condensing pressure and subcooling)”.
2. Set the unit of “Condensing pressure (outlet, absolute)” to kPa and enter 10.
3. Leave “Outlet subcooling (0 = saturated liquid)” at 0.
A subcooling of 0 means “the water leaves the condenser just when all the steam has become water”.
## Step 4: pump
1. A newly placed pump has “Performance given by” set to “Pump efficiency”. Change it to “Isentropic efficiency” (to match the tutorial; for a water pump the two efficiencies differ very little).
2. The isentropic efficiency shows 0.75. Leave it.
3. Leave “Discharge pressure (absolute, optional)” empty.
## Step 5: the whole system's condition (the flow)
Press an empty spot of the canvas; “Calculation conditions (whole cycle)” appears on the right.
1. Leave “Working fluid” at “Water / steam (IAPWS-IF97)”.
2. Leave “Purpose of the calculation” at “Flow given”.
3. In “Point with the given mass flow”, choose “2: Boiler / heater → Turbine”.
4. Enter 10 kg/s as the “Mass flow”.
## Step 6: check the console and calculate
When the conditions are complete, the console says “Structure check: no problems found. Press “▶ Calculate” to solve the cycle.” Press “▶ Calculate” at the right end of the toolbar. The console shows the progress; when it finishes after a few seconds (or a little longer), it shows a summary line such as “Cycle thermal efficiency 36.07 % / net shaft power 11.43 MW / heat input 31.70 MW”. The same numbers appear in “Results (whole system)” on the right (with nothing selected). Part 4 explains how to read them.
## Why the turbine and pump get no outlet pressure: pressure regions
This calculation treats the boiler and the condenser as machines that do not change the pressure of the water and steam (they only heat or cool it). That makes two regions with the same pressure.
Region — Lines — Condition that sets its pressure
high-pressure region — ① (pump → boiler), ② (boiler → turbine) — the boiler's outlet pressure, 10 MPa
low-pressure region — ③ (turbine → condenser), ④ (condenser → pump) — the condenser's condensing pressure, 10 kPa
The pump's outlet (①) is in the same region as the boiler's outlet (②), so setting 10 MPa at the boiler also fixes 10 MPa at the pump outlet. For the same reason the turbine's outlet (③) is fixed by the condenser's 10 kPa. Remember: exactly one pressure per region. Which machine it goes on is up to you — the pump's discharge pressure could take it instead of the boiler (then leave the boiler's outlet pressure empty).
## Make deliberate mistakes
The console's guide appears at every change of an input (without pressing Calculate). Make a few deliberate mistakes to see what it says, then undo them.
Mistake — What the console says
delete the condenser's condensing pressure — No pressure on this pressure level. Give one (e.g. boiler outlet, condenser or a pump / turbine outlet).
give the pump a discharge pressure of 10 MPa as well — Pressure given 2 times on one pressure level (blocks without a pressure change share it). Keep one.
give the turbine an exhaust pressure of 10 kPa as well — the same “Pressure given 2 times”
delete the system's mass flow — The size condition of the calculation mode is missing.
Pressing a guide line selects the machines or lines concerned and takes you to the field to fix. Pressing “▶ Calculate” with the wrong number of conditions does not make the Thermal Cycle CAD drop or add conditions on its own; it stops and shows what is missing or extra.
## Changing a condition after calculating
Change any value after a calculation and the results shown are marked “The conditions have changed: the results shown are those of the previous conditions. Calculate again for the new ones.” Press “▶ Calculate” again to see the results for the new conditions.
## This example has exactly seven conditions
Seven conditions fix the states and the size of the simple Rankine cycle.
- Pressures (two): one per pressure region (boiler outlet 10 MPa, condenser 10 kPa).
- Outlet states of the boiler and condenser (two): boiler outlet temperature 500 °C, condenser subcooling 0 K.
- Performance of the turbine and pump (two): isentropic efficiencies 0.9 and 0.75.
- The cycle's size (one): the flow of 10 kg/s given by the calculation purpose.
Giving the net output or the heat input instead of the flow is explained in calculation purposes and the number of conditions.
## The isentropic efficiency
With the turbine's inlet specific enthalpy h_1, its actual outlet h_2 and the outlet of a loss-free expansion (constant entropy) h_{2s},
\eta_s = \frac{h_1 - h_2}{h_1 - h_{2s}}
For a pump it is the other way round: \eta_s = (h_{2s} - h_1)/(h_2 - h_1) (ideal work ÷ actual work).
## What the check and the calculation each do
- Guide (console): at every edit it checks the structure — the number of pressures per region, the size condition, unconnected ports — without calculating. A clean guide does not guarantee that the cycle solves.
- Calculation: “▶ Calculate” solves the equations of the whole cycle with TESPy. With the wrong number of conditions (missing or extra) it names the machines or state points concerned and does not calculate.
- Units: any unit may be used on screen; the calculation is in SI units (Pa, K, kg/s, W, J/kg). Pressures are absolute.
- Empty means “not given”: an empty field is not 0; it means that condition is not given. Values already in a field (the boiler's 500 °C and so on) are starting values for a calculation, not recommendations.
## Check your answer
Your calculated result should match this shared result. Select each block and compare the entered values (blue) with yours.
Shared result: the simple Rankine cycle (opens without an account or login)
## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).
- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).
- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.