Using the Thermal Cycle CAD and what it assumes — 2 / 12

The screen, placing blocks and drawing lines

This part shows where everything is on the Thermal Cycle CAD's screen and goes step by step through placing the four machines — pump, boiler, turbine, condenser — and joining them with lines into a ring. It also explains the messages shown when a line cannot be drawn and how to fix them, how to delete a wrong line, and the kinds of lines (working fluid, cooling water, shaft).

Calculating a thermal cycle starts with joining the machines into “the path the water goes round”. In the Thermal Cycle CAD the machines are blocks and the pipes between them are lines. A line not only shows from which machine to which the water and steam flow; it is also a state point whose pressure, temperature and so on the calculation finds.

This part enters no numbers yet: it places the four machines of part 1 and joins them into a ring, checking each step.

## Fittings and hoses
A block is like a water fitting joined by hoses. Every fitting has a mouth where water comes in (inlet) and one where it goes out (outlet). A hose always runs from one fitting's outlet to the next fitting's inlet; joining two outlets or two inlets would not let water flow.

And just as a bulb and a battery need a closed loop for a current to flow, a cycle cannot be calculated unless its lines form a ring. Only when the last line returns to the first machine — pump → boiler → turbine → condenser → pump — does it become a “cycle”.

## Getting ready: open the Thermal Cycle CAD
1. Log in and open “Thermal Cycle CAD” from the navigation.
2. If something is already on the canvas (the grid in the middle), press “Empty canvas” in the toolbar (confirm with “OK”).

## Where things are (on a computer)
Place — What is there
Top (toolbar) — the cycle's name, 📘 Tutorials, Empty canvas, Save cycle / Save result / Saved, 🗑 Delete selected, 📊 Results, ▶ Calculate
Left (Blocks) — the machines you can place. “What each block means ?” next to the heading explains each one
Middle (canvas) — where machines are placed and joined with lines; the “line legend” at the top left, zoom buttons at the bottom left
Right (settings) — the fields and results of the selected machine or line; with nothing selected, the calculation conditions of the whole cycle
Bottom (Laplaxian Console) — a black panel that reports, in words, the condition checks and the progress of a calculation
On a phone or tablet the canvas fills the screen, and the block list and the settings slide up from “+ Add equipment” and “Settings & results” at the bottom. Drawing lines takes fine movements, so trying it on a computer first is recommended.

## Step 1: place the four machines
In the “Blocks” list on the left, press Pump, Boiler / heater, Turbine and Condenser once each. Each one is placed on the canvas and its settings appear on the right (no numbers are needed yet).

A placed block shows the machine's name in the middle and small named circles at its sides and bottom. These circles are ports (the mouths that lines connect to).
Port — Where — Circle — Meaning
In (inlet) — left of the block — hollow — where water or steam comes in
Out (outlet) — right of the block — filled — where water or steam goes out
Shaft — bottom of the block (pumps, turbines, …) — — — where turning force (work) is exchanged; not used in this part
## Step 2: arrange them
Drag a block by its name (hold the mouse button down) to move it. Arranged in a square like this, the order the water goes round is easy to see.
— Left — Right
Top row — Boiler / heater — Turbine
Bottom row — Pump — Condenser
The water goes along the top row from left to right (boiler → turbine), down the right column (turbine → condenser), along the bottom row from right to left (condenser → pump) and up the left column (pump → boiler).

Because the bottom row flows from right to left, its lines would otherwise cross over the blocks. Select the condenser and press “⇄ Mirror (inlets on the right)” in the settings on the right; do the same for the pump. Their inlets move to the right and their outlets to the left. Flipping only changes the look; it does not affect the calculation.

## Step 3: draw the lines
Press an outlet circle, hold, move to the inlet circle of the machine to join and let go. Draw the four lines in this order:

1. Pump “Out” → Boiler / heater “In”
2. Boiler / heater “Out” → Turbine “In”
3. Turbine “Out” → Condenser “In”
4. Condenser “Out” → Pump “In”

Each new line gets a circled number ①, ②, ③, ④. These are the state point numbers, given in the order the lines are drawn. A state point is a “place” whose pressure, temperature and so on are found by the calculation; ②, for example, is “the steam leaving the boiler and entering the turbine”. The number can be changed in “State point number (display)” on the right when the line is selected (it does not affect the calculation).

## Step 4: check that the ring is closed
The fourth line closes the ring. Check two things:

- every machine has one line on its inlet and one on its outlet;
- the Laplaxian Console at the bottom no longer shows a red line saying “This port is not connected.” (a port left unconnected is reported with its machine's name; press the line to go to that machine).

No conditions have been entered yet, so the console still says that pressures and other conditions are missing; they come in part 3.

## When a line cannot be drawn
If a connection breaks the rules, no line is drawn and the reason appears above the canvas.
Message — Cause — Fix
Connect an outlet to an inlet. — started from an inlet, or tried to join two outlets or two inlets — draw from a filled circle (outlet) to a hollow one (inlet)
That port is already connected. — a port takes only one line — delete the existing line or use another port (to divide a flow in two, use the “splitter” block)
Fluid and shaft ports cannot be connected. — tried to join a water/steam mouth (inlet or outlet) to a turning mouth (shaft) — join inlets and outlets to each other, shafts to shafts
A block cannot be connected to itself. — drew from a machine's outlet to its own inlet — join it to another machine
A shaft connects a turbine to a generator, pump or compressor, or a motor to a pump or compressor. — wrong shaft direction or partner — draw from the driving shaft (turbine, motor) to the driven one
## Deleting a wrong line or machine
- A line: press it to select it, then press “Delete this connection” on the right (or “🗑 Delete selected” in the toolbar).
- A machine: press it to select it, then press “Delete this block” at the bottom of the right panel. Its lines are deleted with it.
- The Delete key does nothing (so nothing is deleted by accident).

## Kinds of line
The “line legend” at the top left of the canvas lists the kinds of line and what each one carries.
Line — Carries — Appears in
solid — the flow of the working fluid (the water and steam that go round the cycle) with its pressure, temperature and so on — this part on
dotted — cooling water (separate water that never mixes with the working fluid) — the part on a condenser with cooling water
dashed — only the turning force (work) of a shaft; no fluid flows — the part on how performance is given (a generator)
Heat is not carried by lines. The boiler's heat and the heat thrown away in the condenser are shown among the machines' results.

## A shortcut: place it from a tutorial
The same cycle can be placed with “📘 Tutorials” in the toolbar (inside ⋮ on a phone) → “Simple Rankine: the basic steam cycle” → “Place on the canvas”. It already contains the conditions entered in part 3. Compare it with the one you built.

## What lines and state points stand for in the calculation
- One line = one state point: a line carries the mass flow \dot m and the state (pressure p, temperature T, specific enthalpy h, …) of the working fluid at that place. The calculation solves for these values on every line.
- One line per port: dividing or joining flows is the job of the “splitter” and “merge” blocks. A port takes no second line because there would be no equation saying how much flows each way.
- A ring is needed: the calculation assumes a cycle (a closed ring). With an inlet or outlet left open it does not start (“This port is not connected.”).
- Display only: block positions, flipping, display names and state point numbers are for the screen and do not affect the results.
- Line kinds are automatic: solid, dotted and dashed follow from the kinds of port joined (a cooling-water line touches a cooling water inlet or outlet block or a condenser's cooling-water port).

## The finished layout
The layout at the end of step 4 is the same as this shared result (which also has the conditions entered and is calculated).

Shared result: the simple Rankine cycle (opens without an account or login)

## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).

- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).

- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.

Entering conditions and calculating