What is Compressor and turbine maps in the Thermal Cycle CAD (off-design performance)?
The compressor and turbine efficiencies and pressure ratios taken from maps at each operating point (speed and flow). With the public generic maps (from NASA's T-MATS examples) scaled to a design point, the result is an estimate, not the measured performance of any particular machine.
With fixed efficiencies, every operating point of a cycle has the same efficiencies and pressure ratios. In a real gas turbine, changing the turbine inlet temperature or the speed changes the flow, pressure ratio and efficiencies together, and that decides part-load performance. A map tabulates that relation (characteristic lines per speed).
In tutorial 5 (Brayton on compressor and turbine maps), lowering the heated temperature from 1400 K to 1200 K at 3600 rpm lowers the pressure ratio from 10 to about 9.31 and the compressor efficiency from 0.85 to about 0.841 (with fixed efficiencies neither would change).
## Contents
- Choosing a map and its inputs
- Public generic maps (T-MATS)
- How the operating point is solved
- Boundaries, data range and IGV
- Two-shaft machines
- User map format
- What it does not do
### Choosing a map and its inputs
The compressor and turbine blocks choose their Performance model: fixed (as before: the same efficiency and pressure ratio at every operating point), a public generic map or a user map. The Thermal Cycle CAD and Pilot Mode use the same settings, so a cycle need not be rebuilt for the pilot. With a map, the fixed-efficiency settings (efficiency, pressure ratio, discharge pressure ...) do not apply. The mode is usually Operating point from the maps (the flow is a result).
Quantity — Unit — Description — Required / optional
Public generic map — (choice) — HPC, LPC (compressors), HPT, LPT (turbines) of the T-MATS JT9D example. — Required (public map)
User map — (JSON) — A map in the common format (format). — Required (user map)
Design shaft speed — rpm — The map's reference speed is set to it. — Required (scaled to a design point)
Design mass flow — kg/s — Gives the corrected flow (turbine: flow parameter) the map's reference flow is set to. — Required (scaled)
Design inlet total temperature and pressure — K, Pa — For the corrected quantities (absolute). — Required (scaled)
Design pressure ratio (turbine: expansion ratio) — − — Scaled through the ratio minus one. — Required (scaled)
Design isentropic efficiency — − — Scaled by a ratio. — Required (scaled)
Shaft speed (operating point) — rpm — Empty: calculated (from the power balance of a shaft without generator or motor, or from the other conditions). Used for: the corrected speed, i.e. the speed line on the map. — Optional
IGV angle — ° — Only for a user map with a table per IGV angle. Used for: linear interpolation between the tables. — Optional
Map speed and R-line (turbine: expansion ratio) of the design point — − — Empty: the reference recorded with the map. Used for: which point of the map is the design point. — Optional
Mechanical efficiency (turbine) — − — Empty: 1. Used for: shaft output = fluid work × mechanical efficiency. — Optional
The result gives the point on each map (speed, corrected flow, pressure ratio, efficiency, R-line) and the scaling factors. The Maps tab of the results (in Pilot Mode the Map tab below) draws, for compressors, corrected flow against pressure ratio and against efficiency, and for turbines, expansion ratio against flow parameter and against efficiency, with the speed lines, the design point and the operating point. Results on a public map say: “An estimate from a public generic map scaled to the design point. It does not guarantee the measured performance of any particular machine.”
### Public generic maps (T-MATS)
- Source: NASA's T-MATS (https://github.com/nasa/T-MATS , commit ad6e4d5d0d76c229db4eb72ca40ef58d5ddc4014): the numeric arrays of Trunk/TMATS_Examples/Example_JT9D/Simsetup/setup_HPC.m, setup_LPC.m, setup_HPT.m, setup_LPT.m and the design-point coordinates written on the blocks of JT9D_Model_SS.mdl. License: Apache License 2.0 (text in deploy/licenses/T-MATS-LICENSE).
- Nature of the data: the T-MATS README says that its default maps and constants are nonproprietary and public; it does not say whether they are measured or estimated, nor which machine they describe. They are the maps of the JT9D example but are not treated as the measured performance of the JT9D.
- How they were taken: the MATLAB code was not executed; only the numeric arrays were read and converted to the common format. Only units changed: corrected flow lbm/s → kg/s, turbine flow parameter lbm/s·√°R/psia → kg/s·√K/Pa. Nothing was interpolated, smoothed or extended.
- Definitions: compressor flow is the corrected flow W_c=\dot m\sqrt{\theta}/\delta (\theta=T_t/288.15\ \mathrm{K}, \delta=p_t/101.325\ \mathrm{kPa}, T-MATS's 518.67 °R and 14.695951 psia); its speed is relative. The turbines use T-MATS's NPSS form of the block (ConfigNPSS 1): the flow is the flow parameter \dot m\sqrt{T_t}/p_t, without the standard-state ratios, and the speed is N/\sqrt{T_t} scaled into map units. Pressure ratios are total-to-total; efficiencies are total-to-total isentropic (as the blocks compute them from the inlet entropy and the outlet total pressure).
- Reference points (the points taken as the design point): HPC (speed 0.995, R-line 2.0424), LPC (0.993, 1.7664), HPT (99.031, expansion ratio 4.93), LPT (105.038, 6.42), as written on the example's blocks; the example's steady-state run does not use them (iDes = 2).
- Points without data: the LPC table fills the end of its low-speed lines with efficiency 0 at pressure ratio 1. A cell touching an efficiency of 0 is treated as having no data and is not calculated.
### How the operating point is solved
A machine on a map is still a compressor or turbine with an isentropic efficiency (and a pressure ratio). At each operating point the map gives those values, the whole cycle is solved again, and an outer iteration (finite-difference Newton, Broyden updates, line search) continues until all of these hold:
Unknown — Equation
Compressor R-line — solved corrected inlet flow = map corrected flow (corrected speed, R-line)
Inlet temperature of each map machine — equals the solved inlet temperature (it fixes the corrected speed)
Turbine expansion ratio — solved flow parameter = map flow (corrected speed, expansion ratio); when another condition fixes the outlet pressure, it must also equal the solved ratio
Speed of a shaft whose speed is not entered — on a shaft without generator or motor: turbine shaft output = compressor shaft input
Loop flow (mode “operating point from the maps”) — —
If the unknowns and equations do not match, nothing is calculated and both lists are shown (e.g. a given flow together with a given speed fixes the flow twice). The scaling factors are fixed once from the design values and never refitted at an operating point. Trial points outside a map, or with a scaled efficiency outside 0 to 1, are rejected; if no other point solves the equations the calculation fails (nothing is clamped to the edge to converge).
### Boundaries, data range and IGV
- A measured surge line, a stall line of the map's model, a boundary estimated by a model and the end of the recorded data are kept apart.
- The public maps provide no supported surge, stall or choke boundary (not provided). The surge setting of the T-MATS example model is a constant pressure ratio of 30, not a boundary. The highest-flow point of a speed line is not taken as a choke point.
- The end of a speed line is the end of the data. Nothing is calculated outside it (no extrapolation). It is the calculable range, not an operating limit of a machine.
- Without IGV data the IGV is fixed; no opening correction is applied. A user map with IGV angles as a third axis is interpolated linearly between angles.
### Two-shaft machines
With the gas generator (compressor and high-pressure turbine) and the power turbine (with the generator) on separate shafts, each shaft has its own speed and power balance. Leave the gas generator speed empty and it follows from turbine shaft output = compressor shaft input; the pressure between the two turbines is set by the high-pressure turbine's map. Using the public HPT and LPT maps does not make them data of the machine you model.
### User map format
A JSON object with "format": "laplaxian-turbomap-1".
- kind: compressor or turbine. scaling: design_point (scaled to the design point) or none (the map's own values; the design-point settings do not apply).
- speed: {"basis": …, "values": […]}. Compressor bases: corrected (N/\sqrt{T_t/288.15}, rpm) or corrected_relative (scaled only); turbine: corrected, speed_parameter (N/\sqrt{T_t}) or speed_parameter_map_units (scaled only).
- Auxiliary axis: rline (compressor) or expansion_ratio (turbine, inlet over outlet total pressure). Every axis increases, 2 to 60 values.
- Tables ([speed][aux], or [igv][speed][aux]): flow (compressor corrected_flow; turbine flow_parameter or corrected_flow), pressure_ratio (compressor, total_to_total), efficiency (isentropic_total_to_total only; polytropic or total-to-static maps are not reinterpreted and are refused). An efficiency of 0 means no data.
- igv (optional): {"values": [angles…]}. reference (required when scaled): {"speed": …, "rline": …} or {"speed": …, "expansion_ratio": …}.
- limits (optional): surge, stall, choke, each {"status": "measured" | "stall_line" | "estimated" | "not_provided"}. A boundary with points (compressor surge or stall) needs points ([corrected flow, pressure ratio] pairs) and its basis.
### What it does not do
- Dynamics (shaft inertia, storage in volumes). A map gives the machine characteristics of each operating point only.
- Extrapolation, unsupported IGV correction formulas, estimated boundaries.
- Pump maps, a polytropic compressor together with map machines, maps in a measurement balance check.
- Gearboxes (machines on one shaft run at one speed).
## Scaling
From the design values (speed N_d, mass flow \dot m_d, inlet total temperature T_d and pressure p_d, pressure ratio PR_d, efficiency \eta_d) and the map's reference point (speed N_{m,r}, R-line or, for turbines, expansion ratio a_r), the factors are fixed once (the form of T-MATS Compressor_TMATS_body.c, Turbine_TMATS_body.c and pyCycle compressor_map.py, turbine_map.py):
s_N=\frac{N_c(N_d,T_d)}{N_{m,r}},\quad s_W=\frac{W(\dot m_d,T_d,p_d)}{W_m(N_{m,r},a_r)},\quad s_{PR}=\frac{PR_d-1}{PR_m(N_{m,r},a_r)-1},\quad s_\eta=\frac{\eta_d}{\eta_m(N_{m,r},a_r)}
At an operating point N_c=s_N N_m, W=s_W W_m, PR=s_{PR}(PR_m-1)+1, \eta=s_\eta\,\eta_m. The turbine expansion ratio is scaled through PR-1 as well, as checked in the turbine equations of both references.
## Corrected quantities
N_c=\frac{N}{\sqrt{T_t/288.15\ \mathrm{K}}},\quad W_c=\frac{\dot m\sqrt{T_t/288.15\ \mathrm{K}}}{p_t/101.325\ \mathrm{kPa}},\quad W_p=\frac{\dot m\sqrt{T_t}}{p_t}
The corrected flow W_c and the flow parameter W_p are different quantities; each map's recorded definition is used. Kinetic energy is neglected in the Thermal Cycle CAD, so total temperature and pressure are the state-point values.
## Interpolation
Linear on each axis (bilinear, trilinear with IGV; as T-MATS interp2Ac, interp3Ac). Grid values are reproduced exactly. Nothing outside the axes is calculated.
- Results on a public generic map scaled to a design point are estimates, not the measured performance of any machine.
- The public maps provide no supported surge, stall or choke boundary (not provided); no surge margin is evaluated.
- The end of a line is the end of the data, not an operating limit.
- Validation: validation/test_thermal_maps.py (the source numbers, grid values reproduced, units and corrected quantities, the design point reproduced, off-design points on the maps, an independent state chain, the two-shaft power balance, out-of-range and missing boundaries). No comparison with machine or literature performance.