Using the Thermal Cycle CAD and what it assumes — 1 / 12
What is a thermal cycle? The journey of water in a power plant
Before touching the Thermal Cycle CAD, this part introduces what it calculates: the four machines of the Rankine cycle, which boils water, turns a turbine and cools the steam back to water, and the words used throughout the series (pressure, temperature, mass flow, heat and work, specific enthalpy, quality, efficiency), with a kettle and a pinwheel as the picture.
Most thermal and nuclear power plants make electricity by boiling water into steam and letting the steam turn a bladed wheel (a turbine). The used steam is cooled back into water and boiled again. The water goes round the same path again and again, so this repetition is called a thermal cycle.
The Thermal Cycle CAD draws this “path that goes round” on the screen with blocks for the machines and lines between them, and calculates how much heat goes in at each machine and how much work (what becomes electricity) can be taken out.
The goal of this series is that someone using the CAD for the first time can start from placing blocks and drawing lines, build a cycle, calculate it and read the results. Part 1 comes before touching the CAD: it explains what is calculated (the Rankine cycle) and the words that will keep coming up.
## A kettle and a pinwheel
When a kettle boils, steam rushes out of the spout. Put a paper pinwheel in front of the spout and the steam turns it. That is the simplest form of “doing work with heat”.
But once the water runs out, it stops. So a power plant makes a ring:
1. The steam that comes out is not let go; it is cooled back into water.
2. A pump pushes that water back to where it is boiled.
3. It is boiled into steam again and turns the wheel again.
This ring is the Rankine cycle. In this series you first build the simplest Rankine cycle.
## The four machines and what they do
Machine — What it does — What happens to the water and steam
Pump (feed pump) — pushes the water up to a high pressure and sends it to the boiler — stays liquid, its pressure rises; uses a little work (electricity)
Boiler — boils the water with heat from a fuel or similar and makes the steam even hotter — liquid → steam; heat goes in
Turbine (steam turbine) — the steam turns a bladed wheel; a generator on its shaft makes electricity — pressure and temperature fall; work comes out
Condenser — cools the steam with cold water (cooling water) and turns it back into water — steam → liquid; heat is thrown away
The water keeps going pump → boiler → turbine → condenser → pump → …. Heat goes in at the boiler and is thrown away at the condenser; work comes out of the turbine and is used by the pump.
## Isn't throwing heat away a waste?
Throwing heat away in the condenser looks wasteful, but turning the steam back into water matters a great deal. In this series' example, 1 kg of the steam leaving the turbine takes up about 12.4 m³, but as water it takes about 0.001 m³ (one litre). Water with about a ten-thousandth of the volume can be pushed back into the high-pressure boiler with little work. It is also known that no machine can keep turning all the heat put into it into work without throwing any away (the second law of thermodynamics).
## Words used in this series
These words keep appearing in the Thermal Cycle CAD's fields and results. For now it is enough to know that they exist.
Word — Meaning — In this example
Pressure — how hard water or steam pushes on its surroundings. Unit Pa (pascal); 1 atmosphere is about 101 kPa. Pressures in the Thermal Cycle CAD are absolute, measured from vacuum as 0 — boiler outlet 10 MPa (about 100 atmospheres), condenser 10 kPa (about 0.1 atmosphere: far below the outside air, close to a vacuum)
Temperature — in °C or K (kelvin). The value in K = the value in °C + 273.15 — boiler outlet 500 °C, condenser 45.8 °C
Mass flow — the mass of water or steam that flows in one second. Unit kg/s — 10 kg/s (about a bucket of water a second)
Heat and work — both are transfers of energy: heat moves because of a temperature difference, work is handed over by turning a shaft or pushing. Per second they are measured in W (watts); 1 MW = one million W — boiler heat 31.7 MW, turbine work 11.6 MW
Specific enthalpy h — a measure of the energy carried by 1 kg of water or steam. Unit kJ/kg. It rises when heat is received and falls when work is done — boiler inlet 205 kJ/kg → outlet 3375 kJ/kg
Quality x — when water and steam are mixed, the fraction of the mass that is steam. 0 is all water, 1 all steam — turbine outlet 0.847 (85 % steam, 15 % droplets)
Efficiency — the fraction of the heat put in that becomes net work — 36.1 %
Specific enthalpy matters most. Multiply the change of h between a machine's inlet and outlet by the flow, and you have the heat or work that went in or out there. In the boiler, for example, each kilogram receives 3375 − 205 = about 3170 kJ of heat; with 10 kg every second that is about 31.7 MW. The Thermal Cycle CAD solves the cycle so that this holds for all the machines at once (specific enthalpy).
## A look at the answer first
This is the cycle you will build yourself from the next part on, already calculated. It opens as four machines joined by lines.
Shared result: the simple Rankine cycle (opens without an account or login)
Of the 31.7 MW of heat put into the boiler, 11.4 MW (36.1 %) becomes net work. The other 20.3 MW goes to the cooling water in the condenser and is thrown away. Part 4 explains how these numbers are found and read.
## How the series goes on
1. What is a thermal cycle? (this part)
2. The screen, placing blocks and drawing lines
3. Entering conditions and calculating
4. Reading the results: tables and the energy balance
5. Reading the diagrams: T–s and P–h
6. Comparing cases, saving and sharing
7. Later parts go on to the calculation purpose (whether the flow, the heat input or the output is given), how machine performance is given, a condenser with cooling water, reheat and regeneration, refrigeration and gas turbine cycles, and Pilot Mode.
Using the Thermal Cycle CAD needs an account and a login; open it from “Thermal Cycle CAD” in the navigation. Just viewing shared results needs no account.
## Heat and work of each machine
With the mass flow of water and steam \dot m and the specific enthalpies at a machine's inlet and outlet h_{\mathrm{in}} and h_{\mathrm{out}}, in steady operation (nothing changes with time)
Q = \dot m\,(h_{\mathrm{out}} - h_{\mathrm{in}}) \quad\text{(a machine that receives heat: the boiler)}W = \dot m\,(h_{\mathrm{in}} - h_{\mathrm{out}}) \quad\text{(a machine that gives out work: the turbine)}
The pump receives work, so its W is negative; the condenser throws heat away, so its Q is negative. The cycle efficiency is
\eta = \frac{W_{\mathrm{turbine}} - W_{\mathrm{pump}}}{Q_{\mathrm{boiler}}} = \frac{11.569 - 0.135}{31.698} = 0.3607
(in MW).
## What the Thermal Cycle CAD assumes
- Steady state: it calculates states in which nothing changes with time; start-ups and load changes in progress are not calculated.
- A closed cycle: the working fluid (here water and steam) goes round the ring and neither leaves nor enters.
- Lumped machines: each machine is represented by its inlet and outlet states only. Temperature distributions inside, flow speed (kinetic energy) and height (potential energy) are left out.
- Properties: water and steam are calculated with the international formulation IAPWS-IF97 (CoolProp). All pressures are absolute.
- Tools: the equations of the whole cycle are solved with TESPy (a network solver for thermal cycles).
## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).
- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).
- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.