Using the Thermal Cycle CAD and what it assumes — 8 / 12

How performance is given: entering catalogue efficiencies as they are

Catalogue efficiencies divide different things by different things from machine to machine. Giving the pump an overall efficiency with its motor, the turbine a shaft output ratio with a mechanical efficiency and the boiler an efficiency (LHV), and connecting a generator to the turbine's shaft, this part finds the shaft and electric outputs, the fuel heat and the generating efficiency. It explains the assumptions about where losses go and how no loss is counted twice.

So far the turbine's and pump's performance has been given as an “isentropic efficiency”. But the efficiencies in makers' catalogues and in papers are defined in different ways: a pump may list an “overall efficiency including the motor”, a turbine “shaft output ÷ the power of a loss-free expansion”.

Putting a value with a different definition straight into the isentropic efficiency field changes the answer. The Thermal Cycle CAD takes such values under the definition they were written with and converts them itself into what the calculation needs (isentropic efficiencies and so on).

This part gives the simple Rankine cycle built in parts 2 and 3 (boiler outlet 10 MPa and 500 °C, turbine 0.9, condenser 10 kPa, pump 0.75) its performance as follows and connects a generator (efficiency 0.98) to the turbine's shaft (flow 10 kg/s).

- Pump: performance “overall efficiency (motor included)” 0.65, losses “split by entering the motor efficiency”, motor efficiency 0.95
- Turbine: performance “shaft output ÷ loss-free expansion power” 0.88, losses “split by entering the mechanical efficiency”, mechanical efficiency 0.98
- Boiler: fuel given by “boiler efficiency” 0.9, heating value basis LHV

## Where do losses go?
Run a pump for a while and two places get warm: the water in the pump (friction and eddies between the impeller and the water warm it slightly) and the motor (its windings and bearings warm up and the heat escapes to the surrounding air).

Both are “losses”, but they go to different places. A loss that stays in the water raises the temperature (specific enthalpy) of the water leaving the pump; one that escapes to the surroundings leaves the water's state unchanged. A single number such as “overall efficiency 0.65” does not say how much of the loss stayed in the water and how much escaped, so the Thermal Cycle CAD asks you to choose where the losses go.

## An efficiency is “what divided by what”
The same word “efficiency” means different numbers when the top and bottom of the fraction differ. A power plant's efficiency, for example, differs depending on whether it is divided by the heat the water and steam received (cycle efficiency) or by the fuel's heat (generating efficiency) — just as a test score means different things divided by the full mark or by the average.

## How it is used
1. Place a generator from the block list in part 3's cycle.
2. Draw a line from the turbine's “Shaft” at the bottom to the generator's “Shaft”. It becomes a dashed (shaft) line. Leave the generator's conversion efficiency (electric output ÷ shaft input) at 0.98.
3. Set the pump's “Performance given by” to “Overall efficiency (motor included) = water power ÷ electric input” and enter 0.65. Set “Where the losses go” to “split by entering the motor efficiency” and enter 0.95 as the motor efficiency.
4. Set the turbine's “Performance given by” to “shaft output ÷ loss-free expansion power” and enter 0.88. Set “Where the losses go” to “split by entering the mechanical efficiency” and enter 0.98.
5. Set the boiler's fuel setting (under the advanced settings) to “boiler efficiency = heat to the working fluid ÷ fuel heat input”, enter 0.9 and choose LHV as the heating value basis.
6. Press “▶ Calculate”.

When the way performance is given changes, the values entered under the old way are not carried into the new fields; the old values are shown with a note that they are not used because their definition differs. This keeps numbers with different definitions from being reused unnoticed.

## What was entered and what the system converted
Machine — Entered — Converted values and results
Pump — overall efficiency 0.65, motor efficiency 0.95 — pump efficiency 0.6842 (= 0.65 ÷ 0.95), shaft input 147.5 kW, electric input 155.3 kW
Turbine — shaft output ratio 0.88, mechanical efficiency 0.98 — isentropic efficiency 0.8980 (= 0.88 ÷ 0.98), shaft output 11.312 MW, mechanical loss 230.9 kW
Generator — efficiency 0.98 — electric output 11.086 MW
Boiler — boiler efficiency 0.9, LHV — heat to the working fluid 31.685 MW, fuel heat input 35.21 MW
Converted values appear under “converted values” in a machine's results, separate from the values entered.
System — Value — How it is found
Net shaft output — 11.164 MW — turbine shaft output − pump shaft input
Net electric output — 10.930 MW — generator electric output − pump electric input
Cycle efficiency — 35.24 % — net shaft output ÷ heat to the working fluid
Generating efficiency (LHV) — 31.05 % — net electric output ÷ fuel heat input
## What the results tell you
- Taking the losses off one by one: fuel heat 35.21 MW → 31.685 MW reaches the water and steam in the boiler (90 %) → 11.312 MW at the turbine's shaft → 11.086 MW of electricity from the generator → minus the pump's 0.155 MW of electricity gives 10.930 MW. About 31 % of the fuel's heat becomes electricity that can be sent out.
- Nothing counted twice: the pump's overall efficiency includes its motor, so its electric input is subtracted from the net electric output without a motor block. Connecting a motor block as well would count the drive twice, so that is not calculated.
- One efficiency per machine: the turbine's shaft output ratio 0.88 is the product of the expansion losses (isentropic efficiency 0.898) and the mechanical losses of bearings and so on (0.98). An isentropic efficiency and a shaft output ratio cannot both be entered.
- Two different efficiencies: the cycle efficiency is relative to the heat the working fluid received, the generating efficiency to the fuel's heat; the generating efficiency is lower by the boiler efficiency of 0.9 and the other losses.

## Assumptions
- Entered values are kept: the efficiencies you enter stay in the settings; converted values (pump efficiency, isentropic efficiency, fuel heat input, …) appear separately under “converted values” in the machine's results. A result note says which method and assumption were used.
- The formulas: pump efficiency is water power \dot m v_1 \Delta p ÷ shaft input, overall efficiency is water power ÷ electric input, the turbine's shaft output ratio is shaft output ÷ loss-free expansion power \dot m (h_1 - h_{2s}). Each field's ? gives its formula and units.
- Splitting the losses: pump efficiency = overall efficiency ÷ motor efficiency (0.65 ÷ 0.95 = 0.6842); turbine isentropic efficiency = shaft output ratio ÷ mechanical efficiency (0.88 ÷ 0.98 = 0.8980). The losses of the pump or turbine itself go into the working fluid, those of the motor or bearings to the surroundings.
- Efficiencies are constant: an entered efficiency is used at any flow and pressure. Machines whose efficiency changes at part load are given by maps (the part on working fluids and maps).
- Generators and motors are outside the fluid equations: their efficiencies only convert between shaft and electric power.
- Boiler efficiency and heating value: fuel heat input = heat to the working fluid ÷ boiler efficiency. The value differs whether the efficiency is on an HHV (higher) or LHV (lower heating value) basis, so choose the basis. The fuel's combustion itself is not calculated.

Shared result: giving performance as catalogues state it (opens without an account or login)

## How to read a shared result
The link opens the calculated flowsheet as it was (no account or login needed; viewing never recalculates).

- Select a block to see its results and its input conditions on the right (below on a phone).
- The cells of the result tables are painted as entered values (blue, marked “entered”) or calculated values (green). Use the colours to see what was given and what was found.
- Each block shows its own (type) name in large letters and, below it in smaller letters, the name given in this article.
- You can move blocks, but nothing is saved. To change conditions and calculate, build the same flowsheet in your own CAD (sign-up and login required).

## What to try next
- Set the pump's losses to “all warm the water”: how do the outlet temperature and the shaft input change? (The shaft input is no longer determined, so it is not shown.)
- Switch the boiler's basis to HHV: what does the generating efficiency mean now?

- The numbers are calculated with Laplaxian's engine (TESPy 0.11.3, CoolProp 8.0.0; water and steam by IAPWS-IF97). The conditions are chosen for explanation; they are not recommended or standard values.