Tutorial: watching a reaction move along a tube — hydrogen ignition in a PFR

With the Quick Calculate tool “Plug Flow Reactor”, send a hydrogen–air mixture at 930 K through a tube of about 25 mm bore and follow on the charts how temperature and species change along it. Change the inlet temperature, the flow and the cross-section to see how the place and the time of ignition move, and how a calculation with reaction rates differs from chemical equilibrium.

Chemical equilibrium tells you where reactions end up, not how long they take. Designing a reactor needs to know how far the reactions get within a given length and flow. A PFR (plug flow reactor) calculates the reactions of a gas carried along a tube from the reaction rates of the mechanism.

A hydrogen–air mixture at room temperature does not burn on its own. Hot enough — in the upper 900s K — it reacts all at once after a short wait (auto-ignition). This tutorial shows that the wait is a few tens of milliseconds and changes a great deal with a small change in temperature.

Every step can be calculated without logging in. The numbers come from this site's Quick Calculate (reaction mechanism GRI-Mech 3.0). The ignition position is read from the temperature chart as the point where the temperature rises most steeply.

## Step 1: calculate with the initial inputs
1. Open Plug Flow Reactor.
2. Keep the initial inputs: composition H2 2, O2 1, N2 3.76 (“enter moles (mol)”; a stoichiometric hydrogen–air mixture), temperature 930 K, pressure 1 atm, flow given as “volumetric flow (at the tube inlet T and P)” 9 m³/h, length 1 m, cross-section 5 cm² (a tube of about 25 mm inner diameter), “Energy equation” on.
3. Press Calculate.

Result:
- In the main results, “Temperature at the tube outlet” 2383 °C (2656 K), residence time 108.0 ms
- “Velocity at the tube inlet” 5.00 m/s, “Velocity at the tube outlet” 12.54 m/s
- On the temperature chart the temperature jumps at about 23.6 cm from the inlet (47.1 ms). At 20 cm it is still 933 K; at 30 cm it is 2658 K.
- The composition of the “Gas at the tube outlet” (mole fractions) still holds 3.44 % \mathrm{H_2} (29.6 % at the inlet).

Reading it: for the first 20 cm the temperature hardly changes. Meanwhile reactive molecules (radicals) such as \mathrm{H}, \mathrm{O} and \mathrm{OH} build up little by little; once there are enough, the reaction runs away. That is ignition. Choosing \mathrm{OH} on the species chart shows it rising sharply at the ignition point. The gas heats up and expands, so it leaves about 2.5 times faster than it entered.

## Step 2: compare with chemical equilibrium
In Chemical Equilibrium, calculate the same mixture (930 K, 1 atm) under HP.

Result: the equilibrium temperature is 2656.0 K with 3.44 % \mathrm{H_2} — the same as the PFR outlet to the digits shown.

Reading it: about 60 ms pass between ignition and the outlet, so at the end of the 1 m tube the reactions have reached equilibrium. Hydrogen is left not because the reaction is slow but because above 2600 K the equilibrium state itself has part of the \mathrm{H_2O} broken up.

## Step 3: change the inlet temperature
Change only the inlet temperature (flow, length and cross-section as initially; the volumetric flow is at the inlet temperature, so the inlet velocity is 5.00 m/s every time).
Inlet temperature — Ignition position — Time to ignition — Outlet temperature — Outlet velocity
900 K — no ignition within 1 m — — — 909 K — 5.04 m/s
920 K — 43.7 cm — 87.1 ms — 2652 K — 12.66 m/s
930 K — 23.6 cm — 47.1 ms — 2656 K — 12.54 m/s
940 K — 11.0 cm — 22.0 ms — 2660 K — 12.43 m/s
950 K — 4.5 cm — 8.95 ms — 2664 K — 12.32 m/s
1000 K — 0.16 cm — 0.312 ms — 2682 K — 11.81 m/s
Reading it:
- 10 K less at the inlet roughly doubles the time to ignition; between 930 K and 1000 K it differs about 150-fold.
- At 900 K the gas does not ignite in the roughly 200 ms it spends in the tube (29.5 % \mathrm{H_2} at the outlet: hardly anything has reacted).
- For hydrogen and air at 1 atm, around 900–1000 K the reaction that multiplies radicals, \mathrm{H + O_2 \to OH + O}, competes with \mathrm{H + O_2 + M \to HO_2 + M}, which turns \mathrm{H} into the less reactive \mathrm{HO_2}. A small change in temperature therefore changes the time to ignition a great deal.

## Step 4: change the flow and the cross-section
Back at 930 K, change the flow or the cross-section.
Case — Inlet velocity — Outlet velocity — Ignition position — Time to ignition — Residence time
Initial (9 m³/h, 5 cm²) — 5.00 m/s — 12.54 m/s — 23.6 cm — 47.1 ms — 108.0 ms
Twice the flow (18 m³/h) — 10.00 m/s — 25.09 m/s — 47.1 cm — 47.1 ms — 68.1 ms
Half the flow (4.5 m³/h) — 2.50 m/s — 6.27 m/s — 11.8 cm — 47.1 ms — 187.7 ms
Twice the cross-section (10 cm²) — 2.50 m/s — 6.27 m/s — 11.8 cm — 47.1 ms — 187.7 ms
Reading it:
- The time to ignition is 47.1 ms in every case: it depends only on the temperature, pressure and composition of the gas.
- The ignition position is “velocity × time to ignition”, so it moves in proportion to the velocity.
- Halving the flow and doubling the cross-section give the same velocity and hence the same result (the mass flows differ, so the “Flow (mass flow)” in the main results differs).

## Step 5: without the energy equation (isothermal)
Turn “Energy equation” off and calculate (everything else as initially).

Result: the outlet stays at 930 K, the residence time is 201.8 ms and 25.9 % \mathrm{H_2} is left at the outlet.

Reading it: this calculation keeps the gas at 930 K (the reaction heat is taken away). In step 1 the reaction heat warmed the gas, the warmer gas reacted faster, and the loop ran away into ignition. Without it, hydrogen only falls from 29.6 % to 25.9 % by the outlet. The gas neither heats up nor speeds up, so the residence time is longer than in step 1.

## Next
- With H2 1, O2 1, N2 3.76 (a fuel-lean mixture) the outlet is at 2159 K, ignition at 30.6 cm (61.1 ms), with 0.05 % \mathrm{H_2} left (and 9.3 % \mathrm{O_2}). The outlet velocity is 10.62 m/s.
- “Open in Chemical CAD” below the result lets you extend the case into a flowsheet with mixers and heaters.

## The PFR model
A PFR (plug flow reactor) assumes the gas is uniform across the tube and does not mix along it. A small parcel of gas reacts as it travels down the tube, so the reactions are advanced in time t for that parcel (constant pressure):
\frac{dY_k}{dt} = \frac{\dot{\omega}_k W_k}{\rho}, \qquad \frac{dx}{dt} = u = \frac{\dot{m}}{\rho A}
Y_k is the mass fraction of species k, \dot{\omega}_k its net production rate from the mechanism, W_k its molar mass, \rho the density, \dot{m} the mass flow and A the cross-section. With the energy equation the reaction heat raises the gas temperature at constant pressure without heat loss; without it the gas is kept at the inlet temperature.

## Residence time
\tau = \int_0^L \frac{dx}{u} = \int_0^L \frac{\rho A}{\dot{m}}\,dx
When the gas heats up its density falls and its velocity rises, so the residence time cannot be found from the inlet conditions alone (which is why it is longer in step 5). See also residence time.

## Why the time to ignition does not depend on the flow
In the equations above, the progress dY_k/dt is a function of time t without the flow or the cross-section; those appear only in dx/dt = u, which turns time into position. The time to ignition is therefore the same and only the position moves with the velocity (step 4).

- The velocities in this example are 2.5–10 m/s at the inlet and 6–25 m/s at the outlet. This PFR model is at constant pressure and leaves out the kinetic energy of the gas, pressure loss by friction and heat exchange with the wall.
- Mixing along the tube (diffusion) is not modelled, so a flame travelling upstream cannot be calculated with this model.
- The time to ignition depends on the mechanism. GRI-Mech 3.0 was built for natural-gas combustion.
- The numbers are calculated for illustrative inputs; they are not recommended design or standard values.